Followings are the required steps to configure geotel in gen.cfg
file (AKA server based geotel)

1.	Modify vpshost file (Node on which commgrs need to be running)
	in $VPSHOME/common/etc

	Add common component entry into the vpshost file 
	(#COMP	NODE	TYPE )

	0	<NodeName>	common

	<NodeName> is the name of the node on which geotel protocol
	will be running. Make sure that you can ping this <NodeName>
	using the <NodeName> as you will need to put the same <NodeName>
	into commgr.cfg files.

2.	Modify commgr.cfg file (Node on which commgrs need to be running)
	in $VPSHOME/mpsN/etc/commgr.cfg

	Following is a sample example of server based geotel
	configuration in commgr.cfg 

	#
	# Server based Geotel Host Protocol
	#
	host 1 hostname <NodeName> protocol geotel
	host 1 svcid 1-512 unassign
	host 1 svcid 1-192 sess 1
	host 1 svcid 1-192 assignvt 1
	host 1 parameter "vtrange 1-192"

	Note that protocol name in commgr.cfg file should be same as 
	geotel process name in gen.cfg file.

	"vtrange" parameter option must be configured carefully in
	commgr.cfg file.

	If geotel is handling only one commgr connection then
	the vtrange must be 1-<maxvt>. where maxvt is the
	number of phone lines.

	If geotel is handling multiple commgr connections then
	the vtrange must be configured based on the trunk group
	configuration.

	if trunks 1-192 are for commgr A then vtrange in commgr.cfg A
	should 1-192 and if trunks 193-384 are for commgr B then
	vtrange command in commgr.cfg B should be 193-384.

	Please note that the values in the parameter command "vtrange"
	are based on the geotel.cfg file. The assignvt command in
	commgr.cfg must have value 1.

3.	Modify gen.cfg (Node on which geotel needs to be running)
	geotel.cfg in the $VPSHOME/common/etc

	If single geotel needs to be configured:
	---------------------------------------
	Add geotel entry into the gen.cfg file.
	(# NAME	NODE	PORT	is-VOS-CLASS	PRI	COMMAND LINE)

	geotel	-	-	1			0	geotel

	If multiple geotel needs to be configured:
	-----------------------------------------
	Add geotel entries into the gen.cfg file.
	(# NAME	NODE	PORT	is-VOS-CLASS	PRI	COMMAND LINE)

	geotel1	-	-	1			0	geotel
	geotel2	-	-	1			0	geotel

4.  	Create/Modify geotel specific configuration file 
	(Node on which geotel needs to be running) in
	$VPSHOME/common/etc	

	create the geotel specific configuration files based on
	the Process Name based on the column one of the 
	geotel related entry in gen.cfg file.

	If column one has process name as geotel then the configuration
	file name should be geotel.cfg

	If column one has process name as geotel1 then the configuration
	file name should be geotel1.cfg.

	You will need to create configuration files for each geotel
	related entries. Please noet that the port number 
	(TCP ports) for PG connections must be unique in these geotel 
	configuration files.

	If geotel protocol is handling multiple commgr connections then
	geotel configuration should have maxvt and trunks configured
	based on the all commgr phone lines.

	For example:If geotel is configured to handle connections from
			commgr of mps1 (192 lines) and commgr of mps2 (192 lines)
			then maxvt value in geotel.cfg should be 384 and trunk
			ranges must be configured accordingly.
			
5.	New commands:

	from vsh> "geotel1 showcommgr" command has been added to display active commgr connections.

	also vsh> "geotel1 showconf" command now displays number of active commgr connections.

	vsh>"host status" command displays whether geotel process is up
	or down. following is a sample output. Note that Status shows whether
	PG link is up (Host Up) and down (Host down)

	vsh#mps.1,vos/wvets001 {1} -> h1 st
	Host 1
	------
	Type		: GEN Server
	Mode		: screen
	Host Name	: NodeName
	Protocol	: geotel1 [UP]
	Status	: Host Up
	Aid		: enter

	

	