Software Update Name: BCM450.R100.UTPS-130

Applicable H/W Platforms: BCM450

Applicable S/W Platforms: 8.0.1.00, 8.0.1.05

Category: GEN 

Installation Recommendations:
This update should be applied to all new installs of BCM450 Release 1.0.
Existing installations should have this update applied if they are experiencing
any of the issues that are corrected. There is no need to schedule specific
maintenance to apply this upgrade if there are no reported issues. In those 
cases, systems should be updated at the next regular service opportunity. 

Components and Versions:

   utps 2.0.328.52.106

Dependencies: 
Required Updates: 
	- BCM450.R100.SU.System-016.201110 or later

Updates should be applied in the following order:- 
	- BCM450.R100.SU.System-016.201110 or later
	- BCM450.R100.UTPS-130


Product Dependencies: None 

Size: 22.49 MB

System Impact: 
Time to apply approximately 10 minutes

Does update application force reboot: Yes

Other Impacts: None

Limitations: None

Update Removable: No

Description:
------------
The following issues are addressed:

1.Inclusion of UNIStim 5.3 0621C8J,0623C8J,0624C8J and 0625C8J
for IP phones i2007, 1110, 1120e and 1140e respectively. Also,
062AC8J for 1210, 1220 and 1230 sets.

UNIStim Software Release 5.3 provides minor feature enhancements.
Five customer reported cases have been closed and numerous quality 
improvements have been delivered with this UNIStim 5.3 software release.
Visit http://support.avaya.com/css/P8/documents/100152833;CSSSESSIONID=
D2GMTgvRQ2QJjrfkNG5YTnJ4kSxqKJvL9RnN8hRY32SYhGJws8Vr!170487718 for the
detailed bulletin.
wi00970238
  
 
This update includes the content of the following superseded updates:


BCM450.R100.UTPS-109
--------------------
1. A Bluetooth headset can loose connectivity with its paired IP set.
The only way to make it work is to unpair the device, turn off 
Bluetooth on the phone and exit. Then go back in and turn on 
Bluetooth and repeat the pairing sequence.

Inclusion of new UNIStim4.2 firmware solves this issue.
0623C7M,0624C7M and 0625C7M for IP phones 1110, 1120e and 1140e respectively.
062AC7M for Ip phones 1210, 1220 and 1230.
Q02088099


BCM450.R100.UTPS-104
---------------------
1.Inclusion of UNIStim 4.1 firmware release for IP sets
1110/1120E/1140E/1210/1220/1230/2007
Q02124398-01 


BCM450.R100.UTPS-83
---------------------
1.Unable to add the 4th KEM to i2004 sets
When 4th KEM is added to i2004 phase 2 sets, the IP set resets.
This was caused by CoreTel engine sending the messages at a faster rate
than UTPS was able to buffer the messages and send them to the IP set.
The transmit buffer size in UTPS is increased to address the issue.  
Q02067394 

2.i2004 set goes back to default DSCP value for signaling after being restarted
The Unistim terminals are updated with the new DSCP values at every 
boot up to address the issue.
Q01967579-02

 

BCM450.R100.UTPS-73
---------------------

1.i2007 volume fluctuates during calls when using headset 0621C4V 
The issue is with Echo cancellation within the firmware, as it should not lower 
the volume but cut down background noise.

Inclusion of UNIStim3.3 firmware for IP set solves the issue.
0604DCL for Phase II IP Phones (2001, 2002 & 2004).
0621C6P for IP Phone 2007.
0623C6R, 0624C6R, 0625C6R for IP Phone 1110e, 1120e and 1140e respectively.
062AC6R for 1210,1220 and 1230
Q01988838-02

BCM450.R100.UTPS-31
-------------------

1. Inclusion of the UNIStim Firmware Release 3.2 for IP Phones:
0604DCJ for Phase II IP Phones (2001, 2002 & 2004).
0621C6M for IP Phone 2007.
0623C6O, 0624C6O, 0625C6O for IP Phone 1110, 1120E and 1140E respectively.
062AC6O for IP Phone 1210, 1220, and 1230.
Q01998305

2. IP 2004 set with 2 KEMS attached is not registering and keep resetting
The UNIStim3.2 firmware (0604DCJ) fixes the problem with multiple 
KEMs booting up. This firmware is included in this update. 
Q01957461

3. Anomaly with headsets on 1120e IP Phone 
This problem is experienced with the headsets connected to a 1120e IP Phone.
Incoming calls ring on both headset and the phone itself. Also, if the user is on a 
call and a second call comes in the ring tone is heard in the headset as well as 
the set, instead of just the set.
The UNIStim3.2 firmware (0624C6O) fixes the problem which is included in 
this update.
Q01978210

BCM450.R100.UTPS-28
----------------------

1. No speech path after using Hot Desking
This problem is seen when the user tries to invoke/cancel HotDesking when the
IPSet involved in this scenario is in Call Alerting state. The fix for this 
issue is to disallow HotDesking when the IPSets are in 'Call Alerting' state.
Q01809601-01

BCM450.R100.UTPS-7
--------------------

1. The last "L" of the "NEWCALL" softkey is shifted to the next key.
Support has been added so that all the softkey labels which are displayed
on 1110, 1120, 1140 IPSets are in lower case except for the first character.
Q01930775