Software Update Name: BCM.R500.INTOUCH-CLIENT-001

Applicable H/W Platforms: BCM450, BCM50, BCM50a, BCM50e, BCM50b, BCM50ba, BCM50be

Applicable S/W Platforms: 9.0.1.00

Category: GEN

Installation Recommendations:
This InTouch client update should be used with all new installs of BCM450 Release 5.0 
and BCM50 Release 5.0. The InTouch client update is intended for application on Client PC. 
The InTouch client update in not intended for application on BCM using the Element Manager.
Existing installations should have this update applied if they are experiencing any of the issues 
that are corrected. There is no need to schedule specific maintenance to install this client update
if there are no reported issues. In those cases, Client PCs should be updated at the next regular 
service opportunity.

Components & Versions:

InTouch-Client 1.0.0.1701 

Dependencies:
Required Updates: None

Product Dependencies: 

Operating system:
	Windows XP Professional SP3
	Windows Vista SP2 Business, Ultimate or Enterprise (32 OR 64 bit)
	.Net Framework 3.5 Service Pack 1
Microsoft Outlook:
	2002 (XP)
	2003
	2007
Skype (optional):
	3.8.0.188 or later
Windows Live Messenger 2009 (MSN)(optional):
	14.0 or later
BCM Release 5.0 LAN CTE client
Microsoft Exchange:
	2000
	2003
User PC Minimum Hardware Requirements:
	1 GHz 32-bit (x86) or 64-bit (x64) processor
	1 GB of system memory
	20 MB of available space for installation and 10 MB for data
	A Network Connection. 10Mb/s minimum

Size: 10 MB

System Impact:
Time to apply approximately 2 minutes

Does client update application force reboot: No

Other Impacts: None

Limitations: None

Client Update Removable: Yes

InTouch Client Administrator PC Pre-Installation Instructions:
---------------------------------------------------

Full details are in the "Business Communications Manager - InTouch Administration Guide".
LAN CTE client privileges must be configured on the BCM for each user, PC or IP address 
that will use InTouch.
Extract from InTouch client update:
	InTouch setup (InTouch_setup.exe) 
	Configuration Manager (InTouchConfigurationManager.exe)
Download from BCM Release 5.0:
	LAN CTE client installer
Download .Net Framework 3.5 SP1 standalone installer if not installed on user PCs from 
http://www.microsoft.com/net/
Run Configuration Manager (InTouchConfigurationManager.exe) to generate the configuration 
file (SettingsMain.xml) which contains site wide information.
Share the following items for installation on the user PC:
	.NET 3.5 SP1 standalone installer (dotnetfx35.exe) (if not installed on user PC)
	LAN CTE Client Installer
	InTouch setup (InTouch_setup.exe) with configuration file (SettingsMain.xml) in the 
                same directory.

InTouch Client User PC new Installation Instructions:
--------------------------------------------

Full details are in the "Business Communications Manager - InTouch User Guide"
Install the latest LAN CTE Client and .Net Framework 3.5 SP1 before installing InTouch.
Run InTouch_setup.exe provided by the administrator with configuration file 
(SettingsMain.xml) in the same directory.

Existing InTouch User Installation Instructions:

Ensure Outlook is not running on the PC.
Run InTouch_setup.exe provided by the administrator.


Description:
----------------
The following issues are addressed.
 
1. User can receive an error message Intra-company phone number length must be 
   larger than internal extension.
   The user does not see an error message when the intra-company number length 
   entered is the same length as extensions on the system.
   XTRN-932

2. CTE does not accept connections
   When starting Microsoft Outlook, the Nortel InTouch panel can fail to connect 
   to the BCM. Nortel InTouch is not available for that user.
   Q02070415

3. Unused space may appear to the right of the InTouch panel
   XTRN-928

4. InTouch software translations incomplete- button text too long
   XTRN-917

5. InTouch Help files incomplete and help file globalization is missing
   XTRN-649

6. InTouch reports "Session Rejected" when set is in use by another feature   
   When a set used by InTouch has the display updated by One button text, 
   making calls via this DN from InTouch is not possible.
   XTRN-821

7. InTouch should present error when user attempts to set "Forward To" to own number
   If an InTouch user sets their Voicemail DN to match their InTouch-controlled DN and 
  clicks the "Forward to Voicemail" button, the Call Forward fails but no error is displayed.
   XTRN-949

8. InTouch toolbar appears but not InTouch panel
   When using Outlook 2003 version 11.5207.5207 the InTouch panel does not appear
   XTRN-956

9. InTouch Canadian French localization incomplete
   Some items are not localized. Other items are in the wrong language.
   XTRN-962

10.Location settings don't take effect until InTouch is restarted. 
   If no location is set in the Phone and Modem Options InTouch will present the 
   user with the Phone and Modem settings dialog to specify one, the changes made 
   in that dialog don't take effect until InTouch is restarted.
   XTRN-969

This update includes the content of the following superseded InTouch Client updates:

No previous updates