Patch: BCM050.054-CONFIGFS-1.0-1.4

Date:  December 8, 2005

Applicable Platform:  BCM 50 R1, Release 2.04G and 2.04J.

Recommendation:  Non-critical

Component & Version:  CONFIGFS 2.27.0

Dependencies:  None

Size:  Less than 1 mb

System Impact:   Takes less than 1 minute to install.  There will be no interruption to system operation.   Please note and follow the installation instructions below.

Issues Resolved:
Q01147853  After a Level 1 reset, it is not possible to dial into the BCM50 soft modem. The modem answers but it does not complete the handshake and the connection attempt always fails. The issue will only occur after a Level 1 reset because the recovery modem configuration files are incorrect. This patch replaces the current modem configuration files if required and ensures that any subsequent Level 1 reset will maintain the correct versions of the modem configuration files.

Installation instructions:
Given the nature of this issue, if you are able to apply this patch over a modem connection, the BCM has not had a Level 1 reset which is Case 2 below.

Case 1:
If the BCM has had a Level 1 reset, then the modem configuration files will be replaced and modem settings will default.  If you have customized the modem settings, you will have to reprogram the settings after the patch is applied. The modem is configured in the Element Manager under Configuration, Administrator Access, Modem.  After installation of this patch, it is recommended that a back up of system be scheduled.

Case 2:
If the BCM has not had a Level 1 reset, then the current modem configuration files will not be replaced and your modem settings will be maintained.

Limitations:  None