Software Update Name: BCM050.085-MODEM 

Applicable H/W Platforms: BCM50, BCM50a, BCM50e

Applicable S/W Platforms: BCM50 1.00.2.04g, 1.00.2.04j

Category: GEN 

Installation Recommendations: This patch introduces a new feature. It should only be installed for customers wishing to use the new capability to route calls to the modem based on the Calling Number (CLID/ANI). See below for details on this new capability.

Component & Version: Element Manager 522
                     ModemCC 40.15.00.99
                     bcm50EMcartridge 2.0.4.1, 
                     Voice CTI 40.70.04.1
                     openwbem 2.37.0
                     ras-provider 3.1

Dependencies: BCM050.081-SOFTWARE-MANAGEMENT-1.2-1.0. This SOFTWARE-MANAGEMENT patch (or later version) must be applied before BCM050.085-MODEM-1.1-1.2 is applied. If not done, the BCM050.085-MODEM-1.4-1.2 patch may fail to apply.
              
              This patch contains the same version of Voice CTI as does patch BCM050.076-CTI-1.2-1.0, so if BCM050.085-MODEM-1.4-1.2 is applied to a system, there is no need to apply BCM050.076-CTI-1.2-1.0. The converse is not true, as BCM050.085-MODEM-1.4-1.2 contains additional components not included in BCM050.076-CTI-1.2-1.0. 
  
Product Dependencies - Voice CTI, ModemCC, Element Manager, Element Manager Cartridge, MOF and RASProvider are delivered for the Modem Enhancement

Size: 44.6 Mb

System Impact: Time to apply approximately 2 minutes
   Does patch application force reboot: no
   Other: 
    - Voicemail, Call Centre, System Set Based Admin and Modem Call Control will stop and restart
    - This patch includes a new Element Manager (EM) client application. The existing EM client application can be used if only a single BCM50 is managed at any one time. 
      The new EM client application must be installed if EM will used within a mixed environment of BCM50s (i.e. some of which include this new patch, and some of which do not).
    - After the patch is applied, the following procedure is recommended to upgrade Element Manager:
      1. Uninstall all previous versions of BCM50 Element Manager.
      2. Install new version of BCM50 Element Manager.
      3. Where possible, use the new version of BCM50 Element Manager to connect to a BCM50 with this patch applied, across the LAN.
      4. Where possible, use the new version of BCM50 Element Manager to connect to a BCM50 without this patch applied, across the LAN.  At this point, you will be asked to download the cartridge, OK this to download the cartridge.
      
      The above procedure will avoid cartridge download over an analogue modem dial up link, which will take up to 50 minutes.  

      The cartridge download will only be required once.

Limitations: None

Patch Removable: yes

Description:
-----------

The following issues are addressed:

1. This patch introduces a new feature. It is now possible to route an incoming call to the modem based on the calling number (CLID/ANI). Via the Element Manager in the Modem Dial-In panel, a calling number can be programmed. This field will accept a phone number up to 26 digits in length. The BCM50 will redirect calls from this number to the Modem after the number of rings specified in the 'Number of rings' field.

   The system will redirect an incoming call to the Modem DN if either:

    -> The call is presented on the line specified by the 'Line' field. In this case, the call will be redirected after the system has counted the number of rings specified by the 'Number of Rings' field. 
    -> The calling number (CLID/ANI) of the call matches the 'Calling Number' field and the calling Number field is not blank. In this case the call will be redirected after the system has counted the number of rings specified by the 'Number of Rings' field where the counting starts once the calling number has been received. The calling number maybe received from the network at different times depending on the type of trunks and/or the market.

   The line that the modem call is on may "AppearOnly" or "Appear&Ring" or "RingOnly" at one or more sets. These sets will ring (if "Appear&Ring" or "RingOnly" is set) and will show the line in use (if "AppearOnly" or "Appear&Ring" is set) after the call is redirected to the modem DN and the modem answers the call. 

   If Auto-Attendant is configured to answer the line, the number of rings in the CallPilot lines table should be set high enough such that Auto-Attendant will not answer the call before it is redirected to the Modem. 

2. The following issues are resolved as part of the BCM050.076-CTI-1.2-1.0 patch included in this patch:

A. Call Pilot and Call Centre can stop working if a Hunt Group Call is being bounced between one of those applications and the Hunt Group Queue. 
   An example would be an incoming call being answered by Auto-Attendant and transferred to a Hunt Group which has no agents available to answer the call. 
   In this case, the call will bounce back to the Auto-Attendant and it can be transferred back again to the Hunt Group.
 
   CR Q01096293
 
B. Lines are not automatically released when disconnected at the far end when connected to a voice port or a Control DN. Voice Ports and Control DN are under the control of Voice Mail and Call Centre. Certain types of lines will not disconnect immediately when a caller disconnects the call. This feature is to allow the far-end of the call to play a message to the caller (eg. Thank you for calling us...). When a voice port or a Control DN is connected to that type of lines, the call should be released immediately as there those applications don't have the capability to play messages in such cases. 

   CR Q01137108

C. Voice Mail and Call Centre can stop working when the far end of a call connected to those applications via a digital line disconnects at the same time as the application. An example of when this problem is most likely to happen is when a fax transmission is completed between a fax machine and Voice Mail.

   CR Q01197815
 
D. Transferring manually a call to the modem can fail. If the incoming call that was answered came in on a line that was programmed to be answered by the Auto-Attendant, it cannot be manually transferred to the modem for about 30 to 45 seconds.

   CR Q01259566

E. The System can crash or severly misbehave after a long period of use if the Modem or Auto-Attendant were programmed to answer after 1 ring or more. A component is leaking memory every time there is a ring to be counted for Auto-Attendant or the Modem (but not Call Centre). Eventually, the system will run low on available memory and it will cause alarms to be raised and possibly failure on some system features or potentially a system crash. If the system is restarted (power outage or soft reset), the memory will be recovered.

   CR Q01279912-01

F. Calls on Target Lines using only Private Received Digits don't work in a Centralized Voice Mail system. If a customer programs only Private Received digits for the Target Line to be answered by Voice Mail for Centralized Voice Mail (the received digits having to match the Voice Mail DN), Voice Mail will answer the call with the Centralized Auto-Attendant service instead of the Centralized Voice Mail service. This problem doesn't occur of the Public Received Digits are also programmed for that same Target Line.

   CR Q01295164-01


This patch includes the content of the following superseded patches: 

None