Software Update Name: BCM050.115-MONIT-DIALOGGER-SCD

Applicable H/W Platforms:  BCM50, BCM50a, BCM50e, SRG50

Applicable S/W Platforms: 1.00.2.04g, 1.00.2.04j, SRG50

Category: GEN

Installation Recommendations: This patch should be applied to all new installs of BCM50 R1 and SRG50.  Existing installations should have this patch applied if they are experiencing any of the issues that are corrected.  There is no need to schedule specific maintenance to apply this upgrade if there are no reported issues.  In those cases, systems should be updated at the next regular service opportunity.  This patch corrects a number of BCM50 R1 and SRG50 alarm deficiencies identified in final alarms verification testing.  
   The patch eliminates generation of multiple alarms caused by the same fault event and ensures that only the alarm pointing to the root cause of the fault event is generated and displayed, thus reducing the number of unnecessary alarms. It is recommended that this patch be applied to any system being monitored using alarms and/or SNMP.

Component & Version:  
    dialogger-2.04.1-3.ppc.rpm
    monit-4.4-9.ppc.rpm
    scd-2.04.3-1.ppc.rpm

Dependencies:  Required patches - BCM050.096-Service Update #2 

Product Dependencies - None

Size: 0.7 MB

System Impact:  time to apply approximately 1 minute
                Does patch application force reboot:  No
                Other: None

Limitations:  All alarms previously shown in the Element Manager Alarm panel (Administration > General > Alarms) will be cleared after the patch is applied. Historical alarms will be available in the alarm log. Also, any previously-customized alarm settings (Administration > General > Alarm  Settings) will be lost after applying this patch, and will have to be manually re-configured.

Patch Removable: Yes


Description:
-----------
The following issues are addressed:

1. Alarm 391 cannot be generated for UTPS packet loss on IP terminal
   Q01137772 

2. Time Service Event 6003 Inactive on BCM50 REL1
   Q01136800

3. "BRIM is primary clock instead of DTM" alarm NOT reported when DTM-PRI is
used  
   Q01133248

4. Grammar Error on GUI, SNMP text string for PSM Event 11409
   Q01136341

5. USB failure alarms need more detail in resolution field or in description
field
   Q01139367

6. AlarmID 17015 generated when enable or disable modem using SSBA
   Q01158634

7. SNMP strings\EM alarms for Local\Remote Temps not equal to Master Alarms
List
   Q01132292

8. Monit not generating recovery message when you killall CoreTel
   Q01071084


This patch includes the content of the following superseded patches:

None.