#!/bin/bash
#
# init_cleanup
#
# Actions:
# 0. Populate the release_history.info file, using softinv -v and --hist commands.
# 1. Assign weights to class-based priority classes
# 2. Persistent database initial population
# 3. symbolic links for provider agent processes
# 4. population of run level 3 content
# 5. production of monit configuration file
# 6. maintenance of /tmp/osa_ipc, /tmp/scripts, /tmp/startup  directories
# 7. maintenance of startup log files

RETVAL=0

start() {

    # Populate the release_history.info file, using softinv -v and --hist commands.
    # First delete the lock files that would prevent the RPM database from being rebuilt.
    rm -f /var/local/lib/rpm/__db.00?
    # Then rebuild the RPM database.
    /usr/local/bin/rpm --rebuilddb
    echo Software Release: `/nn/bin/softinv -v` > /var/nn/release_history.info
    echo Release History: >> /var/nn/release_history.info
    /nn/bin/softinv --hist >> /var/nn/release_history.info

    # Assign the appropriate weights to the class-based priority classes.
    echo  3       35      50      5       7 > /proc/sys/kernel/sched


    # If PDR database does not exist, track that the component init scripts must be run
    if [ ! -f /var/nn/pdr/current/PersistentConfigData.pdr ]; then
        touch /nn/etc/scd/init_db
    fi

    # Remove all .pid, .ini, .pre files from /var/run
    rm -f /var/run/*.pid
    rm -f /var/run/*.pre
    rm -f /var/run/*.ini

    # Remove the startup sequence stage indication files.
    rm -f /var/run/hc_sanity?

    # If the generic ProviderAgent process exists, create hard symbolic links to the generic ProviderAgent process.
    if [ -f /nn/sbin/ProviderAgent ]; then
        if [ ! -f /nn/sbin/BCMInventoryProviderAgent ];then
            ln -f /nn/sbin/ProviderAgent /nn/sbin/BCMInventoryProviderAgent
        fi
        if [ ! -f /nn/sbin/BCMPerfMonProviderAgent ];then
            ln -f /nn/sbin/ProviderAgent /nn/sbin/BCMPerfMonProviderAgent
        fi
        if [ ! -f /nn/sbin/SoftwareUpdateProviderAgent ];then
            ln -f /nn/sbin/ProviderAgent /nn/sbin/SoftwareUpdateProviderAgent
        fi
        if [ ! -f /nn/sbin/BCMSystemProviderAgent ];then
            ln -f /nn/sbin/ProviderAgent /nn/sbin/BCMSystemProviderAgent
        fi
        if [ ! -f /nn/sbin/BCMUPSProviderAgent ];then
            ln -f /nn/sbin/ProviderAgent /nn/sbin/BCMUPSProviderAgent
        fi
        if [ ! -f /nn/sbin/BCMWebProviderAgent ];then
            ln -f /nn/sbin/ProviderAgent /nn/sbin/BCMWebProviderAgent
        fi
        if [ ! -f /nn/sbin/BackupRestoreProviderAgent ];then
            ln -f /nn/sbin/ProviderAgent /nn/sbin/BackupRestoreProviderAgent
        fi
        if [ ! -f /nn/sbin/BCM_DCMProviderAgent ];then
            ln -f /nn/sbin/ProviderAgent /nn/sbin/BCM_DCMProviderAgent
        fi
        if [ ! -f /nn/sbin/BCM_LicenseProviderAgent ];then
            ln -f /nn/sbin/ProviderAgent /nn/sbin/BCM_LicenseProviderAgent
        fi
        if [ ! -f /nn/sbin/BCM_TimeServiceProviderAgent ];then
            ln -f /nn/sbin/ProviderAgent /nn/sbin/BCM_TimeServiceProviderAgent
        fi
        if [ ! -f /nn/sbin/BCM_TimeZoneSettingProviderAgent ];then
            ln -f /nn/sbin/ProviderAgent /nn/sbin/BCM_TimeZoneSettingProviderAgent
        fi
        if [ ! -f /nn/sbin/BCM_MIB2ProviderAgent ];then
            ln -f /nn/sbin/ProviderAgent /nn/sbin/BCM_MIB2ProviderAgent
        fi
        if [ ! -f /nn/sbin/BCM_HostProviderAgent ];then
            ln -f /nn/sbin/ProviderAgent /nn/sbin/BCM_HostProviderAgent
        fi
        if [ ! -f /nn/sbin/CallPilotProviderAgent ];then
            ln -f /nn/sbin/ProviderAgent /nn/sbin/CallPilotProviderAgent
        fi
        if [ ! -f /nn/sbin/LANProviderAgent ];then
            ln -f /nn/sbin/ProviderAgent /nn/sbin/LANProviderAgent
        fi
     fi

    # Determine if monit application is running.
    # If not, remove existing monit configuration file and build file based on build layer
    # Base, TL, or Full.
    # Also, populate rc3.d based on the same build layer value.
    pidof monit
    if [ $? -ne 0 ]; then
        if [ -f /etc/FULL ]; then
            rm -f /etc/monitrc
            cd /nn/etc/scd/monitcfg
            cat M000A_* M???B_* M???T_* M???F_* M999Z_* > /nn/etc/scd/monitcfg/monitrc.full
            chmod 0700 /nn/etc/scd/monitcfg/monitrc.full
            ln -f /nn/etc/scd/monitcfg/monitrc.full /etc/monitrc
            cp -au /nn/etc/scd/BASE/* /etc/rc.d/rc3.d/
            cp -au /nn/etc/scd/TL/* /etc/rc.d/rc3.d/
            cp -au /nn/etc/scd/FULL/* /etc/rc.d/rc3.d/
        elif [ -f /etc/APPS ]; then
            rm -f /etc/monitrc
            cd /nn/etc/scd/monitcfg
            cat M000A_* M???B_* M???T_* M???F_* M999Z_* > /nn/etc/scd/monitcfg/monitrc.full
            chmod 0700 /nn/etc/scd/monitcfg/monitrc.full
            ln -f /nn/etc/scd/monitcfg/monitrc.full /etc/monitrc
            cp -au /nn/etc/scd/BASE/* /etc/rc.d/rc3.d/
            cp -au /nn/etc/scd/TL/* /etc/rc.d/rc3.d/
            cp -au /nn/etc/scd/FULL/* /etc/rc.d/rc3.d/
        elif [ -f /etc/TL ]; then
            rm -f /etc/monitrc
            cd /nn/etc/scd/monitcfg
            cat M000A_* M???B_* M???T_* M999Z_* > /nn/etc/scd/monitcfg/monitrc.tl
            chmod 0700 /nn/etc/scd/monitcfg/monitrc.tl
            ln -f /nn/etc/scd/monitcfg/monitrc.tl /etc/monitrc
            rm -f /etc/rc.d/rc3.d/S3*
            rm -f /etc/rc.d/rc3.d/S4*
            rm -f /etc/rc.d/rc3.d/S5*
            rm -f /etc/rc.d/rc3.d/S6*
            rm -f /etc/rc.d/rc3.d/S97spagent
            cp -au /nn/etc/scd/BASE/* /etc/rc.d/rc3.d/
            cp -au /nn/etc/scd/TL/* /etc/rc.d/rc3.d/
        elif [ -f /etc/BASE ]; then
            rm -f /etc/monitrc
            cd /nn/etc/scd/monitcfg
            cat M000A_* M???B_* M999Z_* > /nn/etc/scd/monitcfg/monitrc.base
            chmod 0700 /nn/etc/scd/monitcfg/monitrc.base
            ln -f /nn/etc/scd/monitcfg/monitrc.base /etc/monitrc
            rm -f /etc/rc.d/rc3.d/S3*
            rm -f /etc/rc.d/rc3.d/S4*
            rm -f /etc/rc.d/rc3.d/S5*
            rm -f /etc/rc.d/rc3.d/S6*
            rm -f /etc/rc.d/rc3.d/S97spagent
            cp -au /nn/etc/scd/BASE/* /etc/rc.d/rc3.d/
        else 
            # If no build layer indicators, treat as Full product build.
            rm -f /etc/monitrc
            cd /nn/etc/scd/monitcfg
            cat M000A_* M???B_* M???T_* M???F_* M999Z_* > /nn/etc/scd/monitcfg/monitrc.full
            chmod 0700 /nn/etc/scd/monitcfg/monitrc.full
            ln -f /nn/etc/scd/monitcfg/monitrc.full /etc/monitrc
            cp -au /nn/etc/scd/BASE/* /etc/rc.d/rc3.d/
            cp -au /nn/etc/scd/TL/* /etc/rc.d/rc3.d/
            cp -au /nn/etc/scd/FULL/* /etc/rc.d/rc3.d/
        fi
    fi

    # If DiaLogger is not running,
    # - remove /tmp/osa_ipc directory and recreate with 777 permissions,
    # - remove contents of and recreate /tmp/startup directory,
    # - remove contents of and recreate /tmp/scripts directory.

    pidof DiaLogger
    if [ $? -ne 0 ]; then
        if [ -d /tmp/osa_ipc ]; then 
            rm -fr /tmp/osa_ipc
        fi
        mkdir /tmp/osa_ipc
        chmod 777 /tmp/osa_ipc

        if [ -d /tmp/startup ]; then
            rm -fr /tmp/startup
        fi
        mkdir /tmp/startup
        chmod 777 /tmp/startup

        if [ -d /tmp/scripts ]; then
            rm -fr /tmp/scripts
        fi
        mkdir /tmp/scripts
        chmod 777 /tmp/scripts
    fi

    # logrotate the /var/log/messages log file
    if [ -f /etc/messages.conf ]; then
        /usr/sbin/logrotate /etc/messages.conf
    fi

    # Manage the nn_startup log. Keep logs for previous two boot cycles as nn_startup.1 and 
    # nn_startup.2
    if [ -f /var/log/nn_startup.2 ]; then
        rm -f /var/log/nn_startup.2
    fi
    if [ -f /var/log/nn_startup.1 ]; then
        mv /var/log/nn_startup.1 /var/log/nn_startup.2
    fi
    if [ -f /var/log/nn_startup ]; then
        mv /var/log/nn_startup /var/log/nn_startup.1
    fi

    if [ ! -e /var/run/netreport ]; then
        mkdir /var/run/netreport
    fi
}

case "$1" in
  start)
  	start
	;;
  *)
	echo $"Usage: $0 {start}"
	exit 1
esac

exit $?