Software Update Name: BCM050.116-PSM

Applicable H/W Platforms: BCM50, BCM50a, BCM50e, SRG50 1.0

Applicable S/W Platforms: 1.00.2.04g, 1.00.2.04j, SRG50

Category: GEN 

Installation Recommendations: This patch should be applied to all new installs of BCM 50R1 and SRG50. Existing installations should have this patch applied if they are experiencing any of the issues that are corrected. There is no need to schedule specific maintenance to apply this upgrade if there are no reported issues. In those cases, systems should be updated at the next regular service opportunity

Component & Version: psm 4805.2.06.1

Dependencies: Required patches - None 
              Product Dependencies - None

Size: 90 KB

System Impact: time to apply patch ~ 1 min
               Does patch application force reboot: No
               Other - None

Limitations: None

Patch Removable: No

Description:

-----------

The following issue is addressed:

1. FES Router alarms on busy system

   On busy systems the Fast Ethernet Switch may fail to respond to the periodic queries from the Platform Status Monitor (PSM). This resulted in erroneous alarms suggesting that the router (whether present or not) might be defective, and that a LAN port has gone down. This patch corrects that behavior.
   Q01386802

This patch includes the content of the following superseded patches: 

BCM050.009-PSM-1.1-1.0
----------------------

Description: While using NetIQ AppManager to monitor a BCM50, the Memory and CPU Statistics will differ from what is shown using BCM Monitor. If NetIQ AppManager is monitoring a BCM50 that has an APC Smart UPS 750 connected, the system can become unstable. This patch corrects both issues.