Software Update Name: BCM050.R200.149-OSA

Applicable H/W Platforms: BCM50, BCM50a, BCM50e, BCM50b, BCM50ba, BCM50be, SRG50

Applicable S/W Platforms: 2.00.2.05e, SRG50 R2

Category: GEN

Installation Recommendations:
This update should be applied to all new installs of BCM50 R2 and SRG50 2.0.
Existing installations should have this update applied if they are experiencing 
any of the issues that are corrected. There is no need to schedule specific 
maintenance to apply this upgrade if there are no reported issues. In those 
cases, systems should be updated at the next regular service opportunity. 

Components and Versions:
 
   osa 42.1.05.41

  
Dependencies: 
  Required Updates: None
  
  Product Dependencies: None

Size: 0.10 MB

System Impact:
  Time to apply approximately 10 minutes

  Does update application force reboot: Yes

  Other Impacts: 
   All services will be unavailable during the update until the system reboot
   completes.
 
Limitations: None

Update Removable: No

Description:
-----------
The following issues are addressed:

1. Systems locking up after uptime of 497.1 days
   System locks up after uptime of 497.1 days since a 10 ms tick counter rolls over 
   32 bits in 497 days. This update extends the counter bits to 64 bits increasing 
   the number of days to 2^64, much beyond 497 days.
   Q02013912 


This update includes the content of the following superseded updates: 

No previous updates.