Software Update Name: BCM050.R300.AMP-COLUMBIA-177

Applicable H/W Platforms: BCM50, BCM50a, BCM50e, BCM50b, BCM50ba, BCM50be, SRG50

Applicable S/W Platforms: 6.00.2.05, SRG50 R3

Category: LTD 

Installation Recommendations: 
This is a limited distribution update which localizes analog interfaces for the 
SPAIN market profile for use in Columbia. It is intended for use in Columbia and 
any other location which has similar requirements, and should be applied to 
any installations of BCM50 R3 and SRG50 3.0 in this market which is experiencing
issues with echo on Analog Trunks. 

This Analog profile requires the selection of the SPAIN market profile. Please note 
that changing a market profiles in a BCM or SRG will result in a requirement to 
restore configuration data.

Components and Versions:
 
   amp-columbia 1.2.0.15.1

Dependencies: 
   Required Updates:
   -  BCM050.R300.SU.System-169.200903 or later
  
   Updates should be applied in the following order:
  - BCM050.R300.SU.System-169.200903
  - BCM050.R300.AMP-COLUMBIA-177
  
   Product Dependencies: None

Size: 0.1MB

System Impact: 
   Time to apply approximately 10 minutes
   Does update application force reboot: Yes
   Other Impacts: None

Limitations: 
This update should only be applied to BCMs which are using the 
SPAIN market profile, use with any other market profile will result in an alarm.

Update Removable: No

Description:
-----------
The following issues are addressed:

1. Using the SPAIN profile eliminated echo problems on analog trunks in
   Columbian applications. However some other anomalies were seen 
   due to other analog mismatches. This update resolves the issue.
   Q01997351


This update includes the content of the following superseded updates: 

No previous updates.