Field
| Description
|
<severity>
| "***" (critical); "**" (major); "*" (minor); " " (blank for info)
|
<report id>
| The report id consists of an event category (e.g. BUG, ERR, etc.) and an event
number (1200, 230, etc.). It is padded with blanks at the end to ensure it is
9 characters long (4 characters max. for category and 5 digits max. for
number). Examples of report ids are: ERR230, ACD3560, and BUG30.
|
<date>
| DD/MM/YY
|
<time>
| HH:MM:SS
|
<prim_seq_no>
| Primary sequence number of the event (length of 5 digits)
|
<cp_id>
| The Component ID is a 15 character string which indicates the id of the
subsystem generating the alarm
|
<cp_ad>
| The Component address is a 15 character string which indicates the address of
the subsystem generating the event
|
<descriptive text>
| This is an optional string which describes an event
|
<operator data>
| This is an optional field which holds a 160 character string containing extra
text or data to assist the operator in clearing a fault. This field contains
any data output with a filtered SL-1 alarm (e.g. loop number, TN, etc.)
|
<expert data>
| This is an optional variable length character string which contains extra text
or data for a system expert or designer.
|