LD 137: Core Input/Output Diagnostic
LD 137 provides IOP and CMDU related diagnostic and maintenance information
for Option 11C, 51C, 61C, 81 and 81C machines with X11 Release 18 and later. Some
commands in LD 37 can also be used. Refer to that program.
LD 137 provides a means of performing the following functions.
enabling and disabling the CMDU and IOP cards
displaying status and card ID for CMDU and IOP cards
testing the IOP and CMDU (the hard and floppy disk drives are tested)
testing individual disk drives
enabling and disabling disk redundancy
testing SCSI cable connections between IOPs and CMDUs
testing disk synchronization on file or sector levels
during midnight routines performs DATA CMDU, DATA RDUN commands
displaying the Security Device Identification of the Security Dongle
The DATA CMDU AND DATA RDUN midnight routines are run every 5 days.
When a status appears disabled, one or more Out of Service (OOS) messages may
appear. Listed below are the possible OOS messages:
IOP out-of-service
Unexpected interrupt fault monitor threshold exceeded
Fault interrupt fault monitor threshold exceeded
Processor exception fault monitor threshold exceeded
ASIC interrupt fault monitor threshold exceeded
Unrecognized error fault monitor threshold exceeded
General event interrupt fault monitor threshold exceeded
IOP not responding
IOP disabled by craftsperson
IOP responding but cannot be enabled
CMDU out-of-service
Hard disk read error
Hard disk write error
Hard disk drive error
CMDU does not respond, the disk drive may be missing
CMDU has been disabled by the craftsperson
CMDU is disabled because the IOP is out-of-service
Hard disk is inaccessible
CMDUs are not synchronized
CMDU status is mismatched because of a software error
CMDU is in split mode
CMDU is out of split mode
No access to hard disk (HDK)