STAT

Get status of IOPs, CMDUs and Ethernet.

For the IOP, the Enabled or Disabled, and Active or Standby state is printed. Status is given for active and standby IOPs. For the CMDU, Disk redundancy, enabled/disabled, and active/standby status are printed. If Ethernet is disabled, the status (enabled or disabled) is displayed along with an OOS message.

basic-18

The status given for the standby IOP is a software status as it was last seen when that IOP was active. No hardware status is given because the standby IOP cannot be accessed.

For Option 11C: The STAT command is used to get status of PPP and ELNK.

If the status of the IOP or CMDU is disabled, one of the following OOS messages may appear:

• IOP out-of-service

• Unexpected interrupt fault monitor threshold exceeded

• Fault interrupt fault monitor threshold exceeded

• Processor exception fault monitor threshold exceeded

• ASIC interrupt fault monitor threshold exceeded

• Unrecognized error fault monitor threshold exceeded

• General event interrupt fault monitor threshold exceeded

• IOP not responding

• IOP disabled by craftsperson

• IOP responding but cannot be enabled

• CMDU out-of-service

• Hard disk read error

• Hard disk write error

• Hard disk drive error

• CMDU does not respond, the disk drive may be missing

• CMDU has been disabled by the craftsperson

• CMDU is disabled because the IOP is out-of-service

• Hard disk is inaccessible: CMDUs are not synchronized

• CMDU status is mismatched because of a software error

• CMDU is in split mode

• CMDU is out of split mode

• No access to hard disk (HDK)