Prompt
| Response
| Comment
|
REQ:
| CHG
| Change existing data block
|
TYPE:
| TIM_DATA
| Timers
|
CUST
| 0 -99
| Customer number
|
FLSH
| 20 -(45) -768
| Switchhook Flash timing
|
SDFL SDFL>Second
| 384 -(1024) -2048
| Signal Destination Flash timing
|
PHDT
| - -(30) -63
| Permanent Hold Timer
|
DIND
| - -(30) -60
| Dial tone and Interdigit timeout for non-DTMF sets
|
DIDT
| 2 -(14) -60
| Dial tone and Interdigit timeout for DTMF sets
|
LDTT
| 2 -(6) -30
| Line disconnect tone timer for 500/2500 telephones in seconds
|
DLAT
| (0) -120
| Delayed Answer Timer
|
BOTO
| 2 -(14) -60
| Busy tone/Overflow tone Timeout
|
DBRC
| 2 -(60) -120
| Duration Between Reminder Cadences for Audible Reminder of Held Call
|
RTIM
| xxx yyy zzz
| Recall Timers for Slow Answer, Camp-On and Call Waiting
|
ATIM
| (0) -126
| Attendant Alternative Answering Timer
|
AQTT
| - -(30) -255
| Attendant Queue Timing Threshold in seconds
|
ADLD
| (0) -20
| Auto Dial Delay in seconds
|
AFNT
| (0) -126
| Attendant Forward No Answer Timer (must be an even number)
|
AFBT
| (0) - AFNT
| Attendant Forward Buzz Tone (Your entry can be equal to or less than your
response to the AFNT prompt and must be an even number)
|
NFNA
| (0) -63
| Night Forward No Answer or ring cycles
|
NFNS
| (0) -504
| Night Forward No Answer in seconds
|
ADHT
| (0) -14
| Attendant Delay on Hold Timer in seconds
|
HWTT
| 0 -(300) -600
| Length of Howler Tone in seconds
|
NIT
| - -(8)
| Network Alternate Route Selection Interdigit Timer
|
FOPT
| 0 -(14) -30
| Flexible Orbiting Prevention Timer
|