ENLC card
basic-1
Enable and reset specified DTR/MFR card. (Option 11)
If the card resides on a disabled shelf, the status is output and enable is
not performed. If card has been disabled by overload, the overload status entry
is cleared.
This command is also used for Multi-purpose ISDN Signaling Processor (MISP).,
S/T-Interface (SILC), and U-Interface (UILC) line cards.
For Release 21, this command causes the pack to perform a self test. If the
pack self test passes, the LED will blink 3 times. If it fails, the LED will be
lit solidly. A XMI message will be issued to indicate that the XMFR pack has
powered up. This command can be used to enable a XMFR card.
For Options 11C and 11E: ENLC 0 enables all units (0-15) on card 0 if TDS 0 is already enabled. For
Slot 0, the TDS must first be enabled by entering the command ENLX 0 in LD 34.