Contents | Index | Previous | Next

STAT (appl) loop

bri-18

Get status of MISP loop and application.

If appl = BRIL, the status of the BRI Line application is output. If appl = BRIT, the status of the BRI Trunk application is output.

Typical response is:

loop = MISP loop for non-Option 11
mm DSBL nn BUSY
MISP lll : ENBL ACTIVATED timestamp
BRIL : ENBL
BRIT : ENBL

If the card has been manually disabled, the response is:

loop = MISP loop for non-Option 11
DISABLED RESPONDING
MAN DSBL

If the card has been disabled by the system, the response is:

loop = MISP loop for non-Option 11
DISABLED RESPONDING
SYS DSBL - aaa...a

Where aaa...a is the reason as follows:

a
BOOTLOADING = basecode is being downloaded to the MISP

b
FATAL ERROR = MISP has a serious problem

c
OVERLOAD = MISP overload (card inoperable)

d
RESET THRESHOLD = too many resets (card inoperable)

e
SELF TESTING = card is performing self-test

f
SELFTEST FAILED = self-test failed

g
SELFTEST PASSED = successfully completed self-test

h
SHARED RAM TEST FAILED = MISP memory problem (card inoperable)

i
STUCK INTERRUPT  = MISP hardware failure (replace card)

With the STAT BRIL or STAT BRIT option, the response is one of the following:

  1. APPLICATION ENBL

  2. APPLICATION NOT CONFIGURED

  3. APPLICATION NOT RESPONDING

  4. APPLICATION MAN DSBL (manually disabled)

  5. APPLICATION SYS DSBL - aaa..a (system disabled)

Where: aaa...a is the reason as follows:

a
CLOSED = application is closed by basecode on the card

b
CLOSED ERR = error in closing the application

c
CORRUPTED = application is corrupted on the card

d
DOWNLOADING = application is being downloaded

e
ENABLED = application is in active state

f
INACTIVE = application is in inactive state

g
MNT BUSY = application is in maintenance busy state

h
WAIT DSBL = application is in process of being disabled

i
WAIT ENABLE = application is in process of being enabled

j
WAIT ERASE = application is being erased from the card

k
WAIT REMOVE = application is being removed from the card