Contents | Index | Previous | Next

STAT l s c

bri-18

Get status of any specified PE/IPE card. (e.g., digital line, analog, DTR, etc.)

When getting the status of a card relating to a trunk error (STAT), the term RVSD may appear with the trunk information. RVSD indicates that the software has detected a reversed wired trunk for that unit.

When getting the status of a card where ACD sets are defined, the printout will include MSB LOG OUT, MSB LOG IN, LOG IN, OR LOG OUT, according to the ACD set state.

The output format for either a S/T-Interface line card (SILC) or an U-Interface line card (UILC) is:

For BRI trunks:

ll = UNIT ll = DSL/UNIT number on the card =

swstate type L2_state L1_state dch_state clk (mode)

For BRI lines:

ll = UNIT ll = DSL/UNIT number on the card =

swstate type L2_state L1_state

If you are analyzing a SILC or an UILC card, Table 16 on page 136 lists and defines output fields and field responses. An output example can be found page 135.

brsc/basic-19

The output format for an ISDN BRI card is:

loop =
UNIT sw_state DSL misp_state LC_state

With ISDN BRI BRSC cards, the basecode and application status are output.

APPLICATION MAIN STATE SUB STATE/ACTIVATION         TIME
+---------------------+------------------------+---------------------------------------+
BASECODE ENABLED xx/xx/xx x:xx
BRI ENABLED xx/xx/xx x:xx
+---------------------+-------------------------+--------------------------------------+
IDLE 0 BUSY 0 DISABLED 8 MSBY 0
TOTAL DSLS CONFIGURED 8

If you are analyzing an ISDN BRI card , see "STAT l s c d" command for a list of possible states.

Output Example:

00 = UNIT 00 = IDLE LINE ESTA UP
01 = UNIT 01 = IDLE TRNK ESTA UP ESTA SREF (TE)
02 = UNIT 02 = IDLE LINE ESTA DOWN
03 = UNIT 03 = UNEQ
04 = UNIT 04 = UNEQ
05 = UNIT 05 = UNEQ
06 = UNIT 06 = DSBL TRNK DSBL UNEQ RLS (NT)
7 = UNIT 07 = DSBL TRNK DSBL UNEQ RLS (TE)
  

 

Table 16: STAT l s c Field and Response Definitions

Field
Field Definition
Response
Response Definition




swstate
state of DSL/UNIT in software
IDLE
no active call


BUSY
active with a call


UNEQ
unequipped


MBSY
maintenance busy




type
DSL type
LINE
BRI line


TRNK
BRI trunk




L2_state
Layer 2 state of DSL/UNIT in MISP loadware
UNEQ
unequipped


IDLE
no active call


BUSY
active with a call


MBSY
maintenance busy


DSBL
disabled


ESTA
D-channel link is established


RLSU
D-channel link is released


TEST
test mode


RLBT
remote loop back


APDB
application disabled


MPDB
associated MISP disabled


MPNR
associated MISP not responding


UTSM
unable to send message to MISP




L1_state
Layer 1 state of line card
UNEQ
unequipped


DOWN
Layer 1 is down


LCNR
line card not responding


UP
Layer 1 is up


UNDN
undefined DSL state


XPDB
Associated XPEC is disabled


UTSM
unable to send message to MISP




dch_state
State of D-channel link in software
ESTA
D-channel link is established


RLSU
D-channel link is released


TEST-IDLE
test mode idle


TEST-RLBT
test mode remote loop back




clk
Clock mode
DSBL
disabled


PREF
primary reference


SREF
secondary reference




mode
Layer 1 mode of DSL
NT
Network Termination


TE
Terminal Equipment