Basic commands for Fibre Remote IPE

AHIN sl
Print all history file (log file) of Fibre superloop sl
AHIP pc
Print all history file of Fibre Peripheral Controller pc
CDSP
Clears the maintenance display on active CPU to 00 or blank
CMIN
Clear the minor lamp on a system basis
CMIN ALL
Resets minor alarm indication on attendant consoles for all customers
CLPM sl
Clears all performance monitoring counters of Fibre superloop sl (FNET) and its associated FPEC
DSOP sl PRI
Disable optical link of Fibre superloop sl, link Primary
DSOP sl SEC
Disable optical link of Fibre superloop sl, link Secondary
ENOP sl PRI
Enable optical link of Fibre superloop sl, link Primary
ENOP sl SEC
Enable optical link of Fibre superloop sl, link Secondary
FDEF sl
Query default MMI mode on FNET and FPEC of Fibre superloop sl
FNET ALL
Print current status of all Fibre superloops
FNET sl
Print status of Fibre superloop sl (FNET) and its optical packlets
FNTT sl
Test specified Fibre superloop sl (FNET)
FPCT pc
Test specified Fibre peripheral controller pc (FPEC)
FPEC pc
Print status of Fibre peripheral controller pc (FPEC) and its optical packlets
FSTA sl
Print the transmission test status of Fibre superloop sl
FSTP sl
Stop the transmission test. Print test status of Fibre superloop sl.
FTST sl test (h/m/s)
Perform a transmission test of Fibre superloop sl for time h/m/s
MNSN sl
Manual switch on Fibre superloop sl (FNET)
MNSP pc
Manual switch on Fibre peripheral controller pc (FPEC)
NHIN sl
Print new history file of Fibre superloop sl (FNET)
NHIP pc
Print new history file of Fibre peripheral controller pc (FPEC)
PRPM sl
Print performance monitoring report for Fibre superloop sl (FNET) and its associated FPEC
SDEF sl LOC
Set default MMI mode on FNET and FPEC of Fibre superloop sl: MMI mode (Local)
SDEF sl REM