FNET sl

rem_ipe-22

Print status of Fibre superloop sl (FNET) and its optical packlets. The first line prints the general status of the card and includes:

  1. enable/disable status (known by Software)

  2. PLL status

  3. NNDC (indicates that new data calls are disallowed on this superloop)

The next two lines print the status of the packlets:

  1. enable/disable status (known by Firmware)

  2. activity (if selected as active for incoming voice/data)

  3. ALM_LVL - alarm level

  4. ALM_EOI - alarm Electro-Optical Interface (EOI)

Presented below is an example of this general Output format, showing possible values. Bold characters indicate fixed titles.

FNET: n
enabled/disabled
locked / unlocked
NNDC/ <blank>

PACKLETS:
F/W State
Activity
ALM_LVL
ALM_EOI
Primary:
enabled
disabled
transmission tested
RCV
idle
unequipped
S.F.
S.D. No alarm
Rx
Tx
Rx Tx
No alarm
Secondary:
enabled
disabled
transmission tested
RCV
idle
unequipped
S.F.
S.D.
No alarm
Rx
Tx
Rx Tx
No alarm

Where:
  1. unequipped = the optical packlet is physically absent. Firmware treats this as Signal Fail.
  2. S.F. = Signal Fail = Out of service. Loadware either switches to the other link or declares "No active link" if Protection Switching (PS) was not possible.
  3. S.D. = Signal Degradation = Deteriorated performance. Firmware either switches to the other link, or else the data calls are disallowed if Protection Switching (PS) was not possible. Software handles this state as NNDC.
  4. Rx = Receiver alarm
  5. Tx = Transmitter alarm