Automatic diagnostic routines
LD 40 is run in background, during the daily routines, or automatically in
response to CDR faults. It performs the following:
CDR Link test.
CDR Controller status report.
CDR data transmission/loss summary.
Fault indications reported by LD 40 are cleared after their corresponding CDM
message is output. Faults in a multi-port CDR Tape Controller are reported to
all Meridian 1/Meridian SL-1 systems connected to the controller. The fault
records kept for each Meridian 1/Meridian SL-1 are maintained and cleared
independently of each other by the controller.
Loading LD 40 manually runs the automatic fault-clearing routines. Also,
similarly to LD 42, the ''CDMA loaded today'' flag which prevents LD 40 from being
automatically loaded more than once a day are cleared. Thus, manually loading
LD 40 or 42 allows faults detected in the afternoon to be reported, even though
previous faults may have been detected and cleared in the morning.
To run CDMA in background, you must reload LD 40 after a trouble has been
cleared using LD 42. CDM117 X 3 is printed after LD 40 has been reloaded, where X
is the Meridian 1/Meridian SL-1 link or port number. This reload is required so
that the Meridian 1/Meridian SL-1 can react again as soon as another error is
detected.