LD 45: Background Signaling and Switching Diagnostic
This program performs network continuity tests and outputs detected problems
via BSD messages.
The Manual Continuity Test (MCT) allows you to isolate intermittent faulty
points reported by the Background Continuity Test (BCT). For example, BCT reports
faults between A, B, and C. Run the MCT between A and B, then between B and C
to determine how often it fails.
When run in background, LD 45 tests the following on all enabled network
loops:
the continuity of the speech path between each network card and its associated
PE shelves is tested
the continuity of the speech path between all network card is tested
non functioning paths between network cards are identified
Note: When running in background, only new faults detected are output.
For systems running Release 15 and later, memory and signaling tests are only
performed in LD 30. If LD 45 is included in background or midnight routines it
is recommended that LD 30 also be included. By including LD 30, bad memory
areas will be flagged before the continuity tests of LD 45 which will improve fault
isolation.
On Option 11 systems, this Overlay program is not available. Use Overlay
program 30 (LD 30) to perform signaling tests on these systems.