LD 45: Background Signaling and Switching Diagnostic

This program performs network continuity tests and outputs detected problems via BSD messages.

The Manual Continuity Test (MCT) allows you to isolate intermittent faulty points reported by the Background Continuity Test (BCT). For example, BCT reports faults between A, B, and C. Run the MCT between A and B, then between B and C to determine how often it fails.

When run in background, LD 45 tests the following on all enabled network loops:

ld4500000000.gif the continuity of the speech path between each network card and its associated PE shelves is tested

ld4500000000.gif the continuity of the speech path between all network card is tested

ld4500000000.gif non functioning paths between network cards are identified

Note: When running in background, only new faults detected are output.

For systems running Release 15 and later, memory and signaling tests are only performed in LD 30. If LD 45 is included in background or midnight routines it is recommended that LD 30 also be included. By including LD 30, bad memory areas will be flagged before the continuity tests of LD 45 which will improve fault isolation.

On Option 11 systems, this Overlay program is not available. Use Overlay program 30 (LD 30) to perform signaling tests on these systems.