Contents | Index | Previous | Next

Basic commands

CDSP
Clear maintenance display on active CPU to 00 or blank
CMIN ALL
Clear minor alarm indication on all attendant consoles
CMIN c
Clear minor alarm indicator for customer c
DISI loop
Disable loop once it becomes idle
DISL loop
Disable loop
DISS I s
Disable shelf s on loop I
END
Terminate the active command
ENLL loop
Enable loop
ENLS I s
Enable shelf s on loop I
LBKL loop
Close local loop back relay
LBKR loop
Force remote loop back relay
LCNT ALL
List the alarm occurrence counter values for all loops
LCNT loop
Print alarm occurrence counter values on loop
LDIS
List disabled RPE loops in the system
LFLT loop
List speech timeslots that failed loop test
LOCL loop
Perform local loop around test on loop
LOOP loop
Test idle timeslots and speech path continuity on loop
LRPE
List the remote loops in the system
OLBL loop
Remove local loop back on loop
OLBR loop
Remove remote loop back on loop
RCNT ALL
Reset the alarm occurrence counter values for all loops
RCNT loop
Reset the alarm counters for loop
REML loop
Perform remote loop around test on loop
STAT
Get number of busy channels with DISI active
STAT loop
Get status of loop
STAT PSW g
Get status of path switch of RPE group g
STAT RPG g
Get status of RPE group g
SWSP loop
Spare loop
TRPL loop
Test both local and remote end of the RPE loop
TSTL loop
Test local RPE controller of loop
TSTR loop
Test remote RPE controller of loop
UNSP loop
Unspare loop