Loop around test by command

The loop around tests are performed by maintenance personnel on a specified channel of the MFC or MFE S/R card. There are two types of tests:

ld5400000000.gif one is identical to the midnight test which is conducted on the specific channel

ld5400000000.gif the second is conducted on a specific channel for a specified digit and signal level

LD 54 also performs the following functions:

ld5400000000.gif resets all idle MFC or MFE cards once a day during the midnight routines

ld5400000000.gif disables MFC or MFE card or channel. It enables MFC or MFE card or channel

ld5400000000.gif determines the status of MFC card or channel

ld5400000000.gif lists all disabled MFC or MFE channels

ld5400000000.gif handles other common overlay operations (such as clear alarms)

Note 1: Use the DISL command to force-disable the MFC or MFE channel or card.

Note 2: Use the DISI command in LD 32 to disable the card when idle.

Note 3 No more than 50% of MFC channels can be disabled at one time as a result of system or manually initiated tests. However, this constraint does not apply using disable commands.