Contents | Index | Previous | Next
Installing FTC
These steps outline the process to install the FTC feature and change the
default tones and cadences for one or more calling features.
To assist in fault clearing, it is recommended that you keep a record of all
changes.
- Load Overlay 56
- Define new MCAD cadences
- Define new FCAD tones and cadences
- Create one or more FTC tables (one for each trunk route requiring different
tones and cadences)
- Define the non-default tones and cadences for each FTC table
- Enter the FTC table number for each trunk route (LD 16 prompt TTBL)
- If a Conference/TDS/MFS card is equipped, then follow these steps:
a set options in LD 97
b initialize the system (INIT)
c disable and enable each Conf/TDS/MFS card (LD 34)
d disable and enable each Controller (LD 32)
Note 1: The Master Cadence Table (MCAD) defines cadences that are controlled by
software. These are used for single line sets (500/2500) and digital sets.
MCAD can have up to 256 entries (0-255). Each entry can have up to 10 on/off
phases. Entry 0 is reserved for continuous tone and cannot be changed. Entries
are reserved for ringing cadences.
To define an MCAD cadence, enter the time for each on and off phase. Phases
are in 5 ms increments. For example, enter 200 to have a phase last 1 second (200 x 5 ms = 1000 ms = 1 second).
The range for the first phase is 1-9999. The range for the second phase is
0-9999. Once an MCAD entry has been created, it can be changed but not removed.
Note 2: Prompts with the response i bb c tt are only prompted for systems equipped with Tone and Digit cards.
i = internal (0) or external (1) source
bb = burst
cc = cadence
tt = frequency/level
Prompts with the response i bb c tt define the Internal/External source, burst, cadence and frequency/level
respectively. Enter the decimal equivalent (0-15) of the TDS Hex code (refer to
553-2711-180).
The first field is usually 0. If an external source is used the entry is 1 and
the fourth field is 0-7 for the specified channel.
Note 3: The Firmware Cadence Table (FCAD) defines cadences that are controlled by the
NT8D17 Conference /TDS/MFS card. These are used for SL-1 sets.
The FCAD can have up to 256 entries (0-255). Each entry can have up to 10
on-off phases. Entry 0 is reserved for continuous tone and cannot be changed.
FCAD cadences have the following capabilities:
each cadence may be defined to end on the ON phase, OFF phase or repeat after
a single pass through all defined on-off cycles. Any or all of the five on-off
cycles can be repeated.
a unique tone can be defined for each on phase. These tones are permanently
held in the Conference/TDS/MFS firmware.
In order to have the same cadences for 500/2500 Digital and SL-1 sets, the
MCAD and FCAD entries 0 through 15 are identical. Changes to MCAD entries 1
through 15 automatically change MCAD entries 1 through 15. FCAD entries 1 through 15
cannot be changed without changing the MCAD entries.
Note 4: The cadences for Software Controlled Cadence Tones AOBT (Agent Observe Tone),
INTU (Intrusion tone) and OVRD (Override tone) do not repeat in the same manner
as the other tones. All other tones repeat all on-off cycles from the first up
to the fifth if all ten on and off times are programmed. However, these tones
reserve cycle 1 for special use, providing a tone burst of a different length
if desired, to emphasize the initial iteration of the tone cycle.
Note 5: A cycle of 200 3200 50 3200 will have a 200 millisecond tone followed by 3.2
seconds of silence. After this initial burst, the tone will repeat in a 50
millisecond on, 3.2 seconds off pattern as long as the time remains valid. However,
if the pattern is intended to not have an initial burst, the first two entries
must be repeated as the last two entries to obtain the correct sequence.
As an example, if the desired tone is repeating sequence of 50 ms on, 100 ms
off, 100 ms on, 50 ms off, 50 ms on, 3500 ms off, the entry must be as follows:
50 100 100 50 50 3500 50 100