Master Cadence Table (MCAD)
The Master Cadence Table (MCAD) defines cadences that are controlled by
software. These are used for single line sets (500/2500) and digital sets.
The MCAD can have 256 entries (0-255). Each entry can have up to 10 on/off
phases each. Entry 0 is reserved for continuous tone and cannot be changed.
Entries 1-15 are reserved for ringing cadences.
Most of the software cadences are continuously repetitive unless it is
specified that the tone should end after the last phase. There are four exceptions to
this rule: prompts ACBT,AOBT, INTU and OVRD cadences repeat the last 8 phases.
This allows a special initial tone burst to be defined. To have the first cycle
repeat, it must be defined as both the first and last cycle.
A cadence is defined at the CDNC prompt by entering the time for each on and
off phase. The time depends on the settings for the TMRK prompt in LD17 which
defines the software cadence increments as 96 or 128 ms. For each phase, enter
the closest multiple of 5 ms equal to the multiple of 96 or 128 ms which gives
the a time Š the time required.
The range for the first phase is 1-9999. The range for the second phase is
0-9999. Once an MCAD entry has been created, it can be changed but not removed.
For example, given LD 17 TMRK is set to 128 ms, and a repeating 2 seconds on,
4 seconds off cadence is required.
- Determine the ON phase (2 seconds = 2000 ms)
2000/128 = 15.625 = 16 (always round up)
128 x 16 = 2048 ms
multiple of 5 closet to 2048 ms = 2050
Entry for prompt CDNC = 2050/5 = 0410
- Determine the OFF phase (4 seconds = 4000 ms). By using the same calculation,
the entry for prompt CDNC = 0820.
- To define the cadence, respond to the prompts as follows:
REQ NEW, CHG
TYPE MCAD
WCAD 1-255
CDNC 0410 0820
To define the cadence: 2 s on, 4 s off, 4 s on, 2 s off, repeat cycle 1 and 2,
enter:
CDNC 0410 0820 0820 0410
To define the cadence: 2 s on, then steady off, enter:
CDNC 0410, or
CDNC 0410 0000
If an odd number of non-zero phases are entered, software ends the tone after
the last ON phase. Once a zero phase has been entered, it cannot be followed by
non-zero phases. A carriage return at any phase results in zero for the
remaining phases.
Once the cadence is defined, it can be entered in response to the CDNC prompt
for a given feature. For example, CDNC is output after the Call Waiting tone
prompt.