Contents | Index | Previous | Next

ATLP (0), 1

dti/pra-5

Disable (0) or enable (1) daily routine auto loop test. Where:

BULLET.gif
  1. = loop test enable; causes far-end to raise and clear yellow alarm

    BULLET.gif
0 =run the partial loop test; there is no interaction for far-end loop (default value)

LD 60 is included in the daily (midnight) routines if defined by LD 17 prompt DROL. ATLP is only run if LD 60 is included in the daily routines.

BULLET.gifIf ATLP = 1, and all 24 channels on the loop are idle, then the DTI/PRI card is disabled and a self-test is performed on each channel. All DTI/PRI cards are tested, one at a time. If a D-channel is on the loop, it is temporarily released and reestablished. If one or more channels are busy, the test is not performed on the loop.

BULLET.gifIf ATLP = 0, then an
“AUTO TEST DSBL” message is output and only one channel is tested. The channel is randomly selected by software, it cannot be specified.

Automatic Card Test, checks the same functions as the self-test. (Option 11)