Contents | Index | Previous | Next

LCNT (loop)

dti/pra-5

List contents of alarm counters on one or all of the following cases:

Case 1 1.5 Mb/s DTI/PRI

The counters are:

BULLET.gifBPV = bipolar violation counter

BULLET.gifSLIPD = frame slip deletion counter

BULLET.gifSLIPR = frame slip repetition count

BULLET.gifLOSFA = loss of frame alignment counter

BULLET.gifOS_BPV = 24-hr bipolar violation counter

a For PRI with D2, D3, or D4 framing format, 24-hr bipolar violation counter

b For PRI with Extended Superframe Format, 24-hr Cyclic Redundancy Check (CRC) counter

BULLET.gifOS_LOSFA = 24-hr loss of frame alignment counter

BULLET.gifOS_YEL = 24-hr yellow alarm counter

Case 2 2.0 Mb/S DTI

The counters are:

BULLET.gifG1 alarms

BULLET.gifBPV = bipolar violation counter

BULLET.gifFAP = frame alignment threshold counter

BULLET.gifSLP = maintenance threshold slip counter

BULLET.gifCRC = cyclic redundancy threshold counter

BULLET.gifAIS = alarm indication signal

BULLET.gifAIS64 = 64 Kb/s alarm indication signal

BULLET.gifFAL = loss of frame alignment

BULLET.gifMFAL = loss of multiframe alignment

BULLET.gifBIT3 = bit 3 error

BULLET.gifBIT6 = bit 6 error

BULLET.gifCFAS = loss of crc-4 multiframe alignment (Option11 only)

Case 3 2.0 Mb/s PRI

The counters are:

BULLET.gifBPV = bipolar violation counter

BULLET.gifCRC = cyclic redundancy threshold counter

BULLET.gifFAP = frame alignment threshold counter

BULLET.gifSLP = maintenance threshold slip counter

BULLET.gifAIS = alarm indication signal

BULLET.gifLFAS = loss of frame alignment signal

BULLET.gifLMAS = loss of multiframe alignment signal

BULLET.gifRAI = remote alarm indication

BULLET.gifLOS = loss of signal