PLOG DCHI x
pra-13
Get D-channel protocol statistics log for DCHI x.
Protocol errors can be the result of PRI transmission problems and restart
procedures, or a protocol mismatch with the far-end.
The PLOG counters are cleared after the PLOG is printed or the DCHI card is
enabled. When a protocol counter overflows, the PLOG is printed automatically and
the counters are cleared.
Response is:
DCH x I xxxx yy zz 01 02 03. . . 16
Where:
x = DCHI port
xxxx = system real time (in hexadecimal)
yy = maintenance indication primitive
zz = maintenance indication task ID

- 02 03. . . . 16
= protocol error counters as listed below:

- = count of missing PRI handshakes
= count of peer initiated re-establishment link
= count of unsuccessful retransmit N200 of SABME
= count of unsuccessful retransmit N201 of DISC
= count of N(R) errors
= count of I fields with length greater than N201
= count of undefined frames
08 = count of I fields but not allowed
09 = count of FRMR frames
10 = count of CRC error frames
11 = count of REJ frames
12 = count of messages with less than 4 octets
13 = count of undefined protocol discriminators
14 = count of undefined message types
15 = count of messages missing mandatory info. elements
16 = count of messages with undefined information elements