The Multifrequency Sender Diagnostics web page is available only on Large Systems.
Click the Multifrequency Sender Diagnostics link in the list of Maintenance diagnostic tools to open the Multifrequency Sender Diagnostics web page.
The commands available from this web page correspond to the Multifrequency Sender diagnostics traditionally performed using LD 46.
To use the loop commands, do the following:
1 Select one of the following commands from the first Commands drop-down list:
a. STAT - GetStatus of MFS loop
b. ENLL - Enable loop
c. DISL - Disable loop
d. MFS - Test and enable MFS loop
2 Enter the required command parameters in the Command Parameters text box.
3 Click Submit.
To use the card commands, do the following:
1 Select one of the following commands from the second Commands drop-down list:
a. ENLX - Enable Conf/TDS/MFS card on loop
b. DISX - Disable Conf/TDS/MFS card on loop
2 Enter the required command parameters in the Command Parameters text box.
3 Click Submit button.
To use the alarm commands, do the following:
1 Select one of the following commands from the third Commands drop-down list:
a. CMAJ - Clear major alarm and reset power fail
b. CDSP - Clear Main display on active CPU
c. CMIN - Clear minor lamp on system
d. CMIN ALL - Clear minor lamp on attendant consoles
2 Enter the required command parameters in the Command Parameters text box.
3 Click Submit.