Event Code 33600

Severity  MINOR

Description  An error occurred in the Blue Call Router (BCR).  This error indicates that the BCR failed to process Board/DS30/DS0 maintenance commands from the Maintenance SP due to invalid command received.

Impact  Maintenance operations will be affected such as enable and disable CCrs.

Recovery Action  If the problem persists, CrtsyDown system and restart BCR.

Technical Support Action  Run chkdsk to verify files, restart CTM and CT apps, reinstall software if problem persists.

 

Event Code 33601

Severity  DEBUG

Description  The Blue Call Router could not locate ASDN in the MINMAX table

Impact  Unable to delete call from MINMAX table, as a result, the Minimum and Maximum port calculations may not be correct for other calls.

Recovery Action  Reboot server. If problem persists contact Customer Support.

Technical Support Action  Shutdown and restart the BCR.

 

Event Code 33602

Severity  INFO

Description  A call already exists in PCRQ when BCR tries to add a call to PCRQ

Impact  The call will not be inserted to the PCRQ and the operation will be ignored.

Recovery Action  None

Technical Support Action  None

 

Event Code 33603

Severity  CRITICAL

Description  The Symposium Blue Call Router could not create a Semaphore object that is used to synchronize access to its internal data tables. Win32_rc is returned by API CreateSemaphore().

Impact  The BCR will not start. This means that the Symposium Server will not process any calls.

Recovery Action  If the problem persists, contact Customer Support.

Technical Support Action  Check if there are multiple copies of "nbbcrs.exe" running. Shutdown and restart the BCR. Shutdown and restart the CTMS server. Shutdown and restart the NGen server.

 

Event Code 33604

Severity  MINOR

Description  An internal error occurred in the Symposium Blue Call Router (BCR) where the BCR could not get access to the PCR queue for the purpose of destroying the PCRQ by deallocating all elements from the linked list. The Win32_rc is returned by API WaitForSingleObject().

Impact  May affect overall call processing and queuing mechanism.

Recovery Action  Disable and re-enable the port. If the problem persists, contact Customer Support.

Technical Support Action Disable and re-enable the port. If the problem persists, shutdown and re-start the BCR.

 

Event Code 33605

Severity  MINOR

Description  The Symposium Blue Call Router (BCR) could not destroy a Semaphore object, an internal data structure used to hold call information. This is event may occur when the BCR is being shutdown.

Impact  None.

Recovery Action  If the problem persists, contact Customer Support.

Technical Support Action  Shutdown and restart the BCR.

 

Event Code 33606

Severity  MINOR

Description  TAPI error generated when BCR tries to initialize the connection between the audit thread and TAPI.

Impact  Audit thread will not be initiated.

Recovery Action  Restart BCR or contact Customer Support.

Technical Support Action  Restart BCR or contact Customer Support.

 

Event Code 33607

Severity  MINOR

Description  An internal error occurred in BCR.  This error indicates that BCR fails to re-enable back the DS0/device during audit time.

Impact  BCR will try to get redirect limit in next audit time.

Recovery Action  Disable and re-enable the DS0 manually.  If problem persists, check any return codes and restart BCR.

Technical Support Action  Disable and re-enable the DS0 manually.  If problem persists, check any return codes and restart BCR.

 

Event Code 33608

Severity  MINOR

Description  The Blue Call Router could not create and execute the AUDIT thread.  The Audit thread is used only when redirect call is failed.  This thread does recovering process if redirect call failed.

Impact  No recovery is done for bad lockup channel.

Recovery Action  Check any return codes and restart BCR or contact Customer Support.

Technical Support Action  Check any return codes and restart BCR or contact Customer Support.

 

Event Code 33609

Severity  DEBUG

Description  The Blue Call Router could not retrieve an allocated CR in the CR array to check whether it has been allocated to max predefined duration.  

Impact  Not applicable

Recovery Action  Not applicable

Technical Support Action  Not applicable

 

Event Code 33610

Severity  MINOR

Description  The Blue Call Router failed to configure CCr only group after it receives all information about the call in the PCRQ.

Impact  The call will recover to original media type.

Recovery Action  Check previous event logs and the return code.  Check the CT server.

Technical Support Action  Check previous event logs and the return code.  Check the CT server.

 

Event Code 33611

Severity  DEBUG

Description  This event indicates that there was an error detected in BCR during the handling of the NBbcr_SccsInitSession.

Impact  The Initiation of a SCCS VPE Session is rejected.

Recovery Action  Check any return codes and restart BCR or contact Customer Support.

Technical Support Action  Check any return codes and restart BCR or contact Customer Support.

 

Event Code 33612

Severity  DEBUG

Description  This event indicates that there was an error detected in BCR during the handling of the NBbcr_SccsReleaseChannel.

Impact  The channel remains in reserved state. New call to that channel may receive no response.

Recovery Action  Check any return codes and restart BCR or contact Customer Support.

Technical Support Action  Check any return codes and restart BCR or contact Customer Support.

 

Event Code 33613

Severity  DEBUG

Description  This event indicates that there was an error detected in BCR during the handling of the NBbcr_SccsAcceptCall.

Impact  The channel remains in accepted state. No impact expected.

Recovery Action  Check any return codes and restart BCR or contact Customer Support.

Technical Support Action  Check any return codes and restart BCR or contact Customer Support.

 

Event Code 33614

Severity  DEBUG

Description  This event indicates that there was an error detected in BCR during the handling of the NBbcr_SccsReserveChannel.

Impact  Failed to reserve a channel. New call to that channel with receive no response.

Recovery Action  Check any return codes and restart BCR or contact Customer Support.

Technical Support Action  Check any return codes and restart BCR or contact Customer Support.

 

Event Code 33615

Severity  DEBUG

Description  This event indicates that there was an error detected in BCR during the handling of the NBbcr_RsrcMinMaxCheck.

Impact  BCR may not have a proper view of the DSP resource usage. Min/Max limited may not be enforced properly.

Recovery Action  Check any return codes and restart BCR or contact Customer Support.

Technical Support Action  Check any return codes and restart BCR or contact Customer Support.

 

Event Code 33616

Severity  DEBUG

Description  This event indicates that there was an error detected in BCR during the handling of the NBbcr_RsrcConfigUpdate.

Impact  The OM record associated with the call may not be correct. Also BCR may not have a correct view of the DSP resource usage. Min/Max limited may not be enforced properly.

Recovery Action  Check any return codes and restart BCR or contact Customer Support.

Technical Support Action  Check any return codes and restart BCR or contact Customer Support.

 

Event Code 33617

Severity  MINOR

Description  This event indicates a duplicated om id was error detected in NBbcr_RsrcConfigBegin.

Impact  The OM record associated with the call may not be correct.

Recovery Action  Check previous event logs and the return code.  Restart OM server and BCR.

Technical Support Action  Check previous event logs and the return code.  Restart OM server and BCR.

 

Event Code 33618

Severity  MINOR

Description  This error indicates that the BCR could not return a Port to the idle resource queue while enabling a port.

Impact  The affected channel is not available to handle call.

Recovery Action  Disable and enable the affected channel.

Technical Support Action  Check previous event logs and the return code.  Restart BCR.

 

Event Code 33619

Severity  DEBUG

Description  This error indicates that the BCR received a group configuration completion at an unexpected internal Configuration state.

Impact  The affected channel is not available to handle call.

Recovery Action  Disable and enable the affected channel.

Technical Support Action  Check previous event logs and the return code.  Restart BCR.

 

Event Code 33620

Severity  DEBUG

Description  This error indicates that the BCR received a group configuration completion at an unexpected internal CCr state.

Impact  The affected channel is not available to handle call.

Recovery Action  Disable and enable the affected channel.

Technical Support Action  Check previous event logs and the return code.  Restart BCR.

 

Event Code 33621

Severity  MINOR

Description  This error indicates that the BCR failed to enable a channel (MSL100 Connectivity only).

Impact The affected channel is not available to handle call.

Recovery Action  Disable and enable the affected channel

Technical Support Action  Check previous event logs and the return code.  Restart BCR.

 

Event Code 33622

Severity  MINOR

Description  This error indicates that the BCR failed to disable a channel (MSL100 Connectivity only).

Impact  The affected channel is not available to handle call.

Recovery Action  Disable and enable the affected channel

Technical Support Action  Check previous event logs and the return code.  Restart BCR.