Event Code: 37400

Severity Critical

Description The Diagnostic could not read from SRAM memory of the indicated Board's second DSP.

Impact The DSP's memory elements could be faulty. The DSP may not be able to be used for call processing.

Recovery Action The DSP's on-board memory elements could be defective. Run the DSP Diagnostics to confirm the result of the diagnostic. Please contact your technical support organization for additional instructions.

Technical Support Action The DSP's on-board memory elements could be defective. Run the DSP Diagnostics to confirm that the DSP is defective. Try replacing the DSP with one that is known to function correctly and re-run the diagnostic.

 

Event Code: 37401

Severity Critical

Description The Diagnostic could not read from SRAM memory of the indicated Board's third DSP.

Impact The DSP's memory elements could be faulty. The DSP may not be able to be used for call processing.

Recovery Action The DSP's on-board memory elements could be defective. Run the DSP Diagnostics to confirm the result of the diagnostic. Please contact your technical support organization for additional instructions.

Technical Support Action The DSP's on-board memory elements could be defective. Run the DSP Diagnostics to confirm that the DSP is defective. Try replacing the DSP with one that is known to function correctly and re-run the diagnostic.

 

Event Code: 37402

Severity Critical

Description The Diagnostic could not read from SRAM memory of the indicated Board's fourth DSP.

Impact The DSP's memory elements could be faulty. The DSP may not be able to be used for call processing.

Recovery Action The DSP's on-board memory elements could be defective. Run the DSP Diagnostics to confirm the result of the diagnostic. Please contact your technical support organization for additional instructions.

Technical Support Action The DSP's on-board memory elements could be defective. Run the DSP Diagnostics to confirm that the DSP is defective. Try replacing the DSP with one that is known to function correctly and re-run the diagnostic.

 

Event Code: 37403

Severity Critical

Description The Diagnostic could not read from SRAM memory of the indicated Board's fifth DSP.

Impact The DSP's memory elements could be faulty. The DSP may not be able to be used for call processing.

Recovery Action The DSP's on-board memory elements could be defective. Run the DSP Diagnostics to confirm the result of the diagnostic. Please contact your technical support organization for additional instructions.

Technical Support Action The DSP's on-board memory elements could be defective. Run the DSP Diagnostics to confirm that the DSP is defective. Try replacing the DSP with one that is known to function correctly and re-run the diagnostic.

 

Event Code: 37404

Severity Critical

Description The Diagnostic could not read from SRAM memory of the indicated Board's sixth DSP.

Impact The DSP's memory elements could be faulty. The DSP may not be able to be used for call processing.

Recovery Action The DSP's on-board memory elements could be defective. Run the DSP Diagnostics to confirm the result of the diagnostic. Please contact your technical support organization for additional instructions.

Technical Support Action The DSP's on-board memory elements could be defective. Run the DSP Diagnostics to confirm that the DSP is defective. Try replacing the DSP with one that is known to function correctly and re-run the diagnostic.

 

Event Code: 37405

Severity Critical

Description The Diagnostic could not write to SRAM memory of the indicated Board's first DSP.

Impact The DSP's memory elements could be faulty. The DSP may not be able to be used for call processing.

Recovery Action The DSP's on-board memory elements could be defective. Run the DSP Diagnostics to confirm the result of the diagnostic. Please contact your technical support organization for additional instructions.

Technical Support Action The DSP's on-board memory elements could be defective. Run the DSP Diagnostics to confirm that the DSP is defective. Try replacing the DSP with one that is known to function correctly and re-run the diagnostic.

 

Event Code: 37406

Severity Critical

Description The Diagnostic could not write to SRAM memory of the indicated Board's second DSP.

Impact The DSP's memory elements could be faulty. The DSP may not be able to be used for call processing.

Recovery Action The DSP's on-board memory elements could be defective. Run the DSP Diagnostics to confirm the result of the diagnostic. Please contact your technical support organization for additional instructions.

Technical Support Action The DSP's on-board memory elements could be defective. Run the DSP Diagnostics to confirm that the DSP is defective. Try replacing the DSP with one that is known to function correctly and re-run the diagnostic.

 

Event Code: 37407

Severity Critical

Description The Diagnostic could not write to SRAM memory of the indicated Board's third DSP.

Impact The DSP's memory elements could be faulty. The DSP may not be able to be used for call processing.

Recovery Action The DSP's on-board memory elements could be defective. Run the DSP Diagnostics to confirm the result of the diagnostic. Please contact your technical support organization for additional instructions.

Technical Support Action The DSP's on-board memory elements could be defective. Run the DSP Diagnostics to confirm that the DSP is defective. Try replacing the DSP with one that is known to function correctly and re-run the diagnostic.

 

Event Code: 37408

Severity Critical

Description The Diagnostic could not write to SRAM memory of the indicated Board's fourth DSP.

Impact The DSP's memory elements could be faulty. The DSP may not be able to be used for call processing.

Recovery Action The DSP's on-board memory elements could be defective. Run the DSP Diagnostics to confirm the result of the diagnostic. Please contact your technical support organization for additional instructions.

Technical Support Action The DSP's on-board memory elements could be defective. Run the DSP Diagnostics to confirm that the DSP is defective. Try replacing the DSP with one that is known to function correctly and re-run the diagnostic.

 

Event Code: 37409

Severity Critical

Description The Diagnostic could not write to SRAM memory of the indicated Board's fifth DSP.

Impact The DSP's memory elements could be faulty. The DSP may not be able to be used for call processing.

Recovery Action The DSP's on-board memory elements could be defective. Run the DSP Diagnostics to confirm the result of the diagnostic. Please contact your technical support organization for additional instructions.

Technical Support Action The DSP's on-board memory elements could be defective. Run the DSP Diagnostics to confirm that the DSP is defective. Try replacing the DSP with one that is known to function correctly and re-run the diagnostic.

 

Event Code: 37410

Severity Critical

Description The Diagnostic could not write to SRAM memory of the indicated Board's sixth DSP.

Impact The DSP's memory elements could be faulty. The DSP may not be able to be used for call processing.

Recovery Action The DSP's on-board memory elements could be defective. Run the DSP Diagnostics to confirm the result of the diagnostic. Please contact your technical support organization for additional instructions.

Technical Support Action The DSP's on-board memory elements could be defective. Run the DSP Diagnostics to confirm that the DSP is defective. Try replacing the DSP with one that is known to function correctly and re-run the diagnostic.

 

Event Code: 37411

Severity Critical

Description The Diagnostic could not write to I/O REGISTER memory of the indicated Board's first DSP.

Impact The DSP's memory elements could be faulty. The DSP may not be able to be used for call processing.

Recovery Action The DSP's on-board memory elements could be defective. Run the DSP Diagnostics to confirm the result of the diagnostic. Please contact your technical support organization for additional instructions.

Technical Support Action The DSP's on-board memory elements could be defective. Run the DSP Diagnostics to confirm that the DSP is defective. Try replacing the DSP with one that is known to function correctly and re-run the diagnostic.

 

Event Code: 37412

Severity Critical

Description The Diagnostic could not write to I/O REGISTER memory of the indicated Board's second DSP.

Impact The DSP's memory elements could be faulty. The DSP may not be able to be used for call processing.

Recovery Action The DSP's on-board memory elements could be defective. Run the DSP Diagnostics to confirm the result of the diagnostic. Please contact your technical support organization for additional instructions.

Technical Support Action The DSP's on-board memory elements could be defective. Run the DSP Diagnostics to confirm that the DSP is defective. Try replacing the DSP with one that is known to function correctly and re-run the diagnostic.

 

Event Code: 37413

Severity Critical

Description The Diagnostic could not write to I/O REGISTER memory of the indicated Board's third DSP.

Impact The DSP's memory elements could be faulty. The DSP may not be able to be used for call processing.

Recovery Action The DSP's on-board memory elements could be defective. Run the DSP Diagnostics to confirm the result of the diagnostic. Please contact your technical support organization for additional instructions.

Technical Support Action The DSP's on-board memory elements could be defective. Run the DSP Diagnostics to confirm that the DSP is defective. Try replacing the DSP with one that is known to function correctly and re-run the diagnostic.

 

Event Code: 37414

Severity Critical

Description The Diagnostic could not write to I/O REGISTER memory of the indicated Board's fourth DSP.

Impact The DSP's memory elements could be faulty. The DSP may not be able to be used for call processing.

Recovery Action The DSP's on-board memory elements could be defective. Run the DSP Diagnostics to confirm the result of the diagnostic. Please contact your technical support organization for additional instructions.

Technical Support Action The DSP's on-board memory elements could be defective. Run the DSP Diagnostics to confirm that the DSP is defective. Try replacing the DSP with one that is known to function correctly and re-run the diagnostic.

 

Event Code: 37415

Severity Critical

Description The Diagnostic could not write to I/O REGISTER memory of the indicated Board's fifth DSP.

Impact The DSP's memory elements could be faulty. The DSP may not be able to be used for call processing.

Recovery Action The DSP's on-board memory elements could be defective. Run the DSP Diagnostics to confirm the result of the diagnostic. Please contact your technical support organization for additional instructions.

Technical Support Action The DSP's on-board memory elements could be defective. Run the DSP Diagnostics to confirm that the DSP is defective. Try replacing the DSP with one that is known to function correctly and re-run the diagnostic.

 

Event Code: 37416

Severity Critical

Description The Diagnostic could not write to I/O REGISTER memory of the indicated Board's sixth DSP.

Impact The DSP's memory elements could be faulty. The DSP may not be able to be used for call processing.

Recovery Action The DSP's on-board memory elements could be defective. Run the DSP Diagnostics to confirm the result of the diagnostic. Please contact your technical support organization for additional instructions.

Technical Support Action The DSP's on-board memory elements could be defective. Run the DSP Diagnostics to confirm that the DSP is defective. Try replacing the DSP with one that is known to function correctly and re-run the diagnostic.

 

Event Code: 37417

Severity Critical

Description The Diagnostic failed to form a connection between two channels on the indicated Board's first DSP. Timeswitch software returned an error for a "Connect" request.

Impact The Timeswitch's memory elements could be faulty. Call processing using the indicated Board's first could be greatly impacted.

Recovery Action The Timeswitch's memory elements could be faulty. Run the Timeswitch Memory Diagnostic, and then re-run the diagnostic which failed to further test the behavior of the Timeswitch.

Technical Support Action The Timeswitch's memory elements could be faulty. Run the Timeswitch Memory Diagnostic, and then re-run the diagnostic which failed to further test the behavior of the Timeswitch.

 

Event Code: 37418

Severity Critical

Description The Diagnostic failed to form a connection between two channels on the indicated Board's second DSP. Timeswitch software returned an error for a "Connect" request.

Impact The Timeswitch's memory elements could be faulty. Call processing using the indicated Board's first could be greatly impacted.

Recovery Action The Timeswitch's memory elements could be faulty. Run the Timeswitch Memory Diagnostic, and then re-run the diagnostic which failed to further test the behavior of the Timeswitch.

Technical Support Action The Timeswitch's memory elements could be faulty. Run the Timeswitch Memory Diagnostic, and then re-run the diagnostic which failed to further test the behavior of the Timeswitch.

 

Event Code: 37419

Severity Critical

Description The Diagnostic failed to form a connection between two channels on the indicated Board's third DSP. Timeswitch software returned an error for a "Connect" request.

Impact The Timeswitch's memory elements could be faulty. Call processing using the indicated Board's first could be greatly impacted.

Recovery Action The Timeswitch's memory elements could be faulty. Run the Timeswitch Memory Diagnostic, and then re-run the diagnostic which failed to further test the behavior of the Timeswitch.

Technical Support Action The Timeswitch's memory elements could be faulty. Run the Timeswitch Memory Diagnostic, and then re-run the diagnostic which failed to further test the behavior of the Timeswitch.

 

Event Code: 37420

Severity Critical

Description The Diagnostic failed to form a connection between two channels on the indicated Board's fourth DSP. Timeswitch software returned an error for a "Connect" request.

Impact The Timeswitch's memory elements could be faulty. Call processing using the indicated Board's first could be greatly impacted.

Recovery Action The Timeswitch's memory elements could be faulty. Run the Timeswitch Memory Diagnostic, and then re-run the diagnostic which failed to further test the behavior of the Timeswitch.

Technical Support Action The Timeswitch's memory elements could be faulty. Run the Timeswitch Memory Diagnostic, and then re-run the diagnostic which failed to further test the behavior of the Timeswitch.

 

Event Code: 37421

Severity Critical

Description The Diagnostic failed to form a connection between two channels on the indicated Board's fifth DSP. Timeswitch software returned an error for a "Connect" request.

Impact The Timeswitch's memory elements could be faulty. Call processing using the indicated Board's first could be greatly impacted.

Recovery Action The Timeswitch's memory elements could be faulty. Run the Timeswitch Memory Diagnostic, and then re-run the diagnostic which failed to further test the behavior of the Timeswitch.

Technical Support Action The Timeswitch's memory elements could be faulty. Run the Timeswitch Memory Diagnostic, and then re-run the diagnostic which failed to further test the behavior of the Timeswitch.

 

Event Code: 37422

Severity Critical

Description The Diagnostic failed to form a connection between two channels on the indicated Board's sixth DSP. Timeswitch software returned an error for a "Connect" request.

Impact The Timeswitch's memory elements could be faulty. Call processing using the indicated Board's first could be greatly impacted.

Recovery Action The Timeswitch's memory elements could be faulty. Run the Timeswitch Memory Diagnostic, and then re-run the diagnostic which failed to further test the behavior of the Timeswitch.

Technical Support Action The Timeswitch's memory elements could be faulty. Run the Timeswitch Memory Diagnostic, and then re-run the diagnostic which failed to further test the behavior of the Timeswitch.

 

Event Code: 37423

Severity Critical

Description The Diagnostic failed to remove a connection between two channels on the indicated Board's first DSP. Timeswitch software returned an error for a "Disconnect" request.

Impact The Timeswitch's memory elements could be faulty. Call processing using the indicated Board's first could be greatly impacted.

Recovery Action The Timeswitch's memory elements could be faulty. Run the Timeswitch Memory Diagnostic, and then re-run the diagnostic which failed to further test the behavior of the Timeswitch.

Technical Support Action The Timeswitch's memory elements could be faulty. Run the Timeswitch Memory Diagnostic, and then re-run the diagnostic which failed to further test the behavior of the Timeswitch.

 

Event Code: 37424

Severity Critical

Description The Diagnostic failed to remove a connection between two channels on the indicated Board's second DSP. Timeswitch software returned an error for a "Disconnect" request.

Impact The Timeswitch's memory elements could be faulty. Call processing using the indicated Board's first could be greatly impacted.

Recovery Action The Timeswitch's memory elements could be faulty. Run the Timeswitch Memory Diagnostic, and then re-run the diagnostic which failed to further test the behavior of the Timeswitch.

Technical Support Action The Timeswitch's memory elements could be faulty. Run the Timeswitch Memory Diagnostic, and then re-run the diagnostic which failed to further test the behavior of the Timeswitch.

 

Event Code: 37425

Severity Critical

Description The Diagnostic failed to remove a connection between two channels on the indicated Board's third DSP. Timeswitch software returned an error for a "Disconnect" request.

Impact The Timeswitch's memory elements could be faulty. Call processing using the indicated Board's first could be greatly impacted.

Recovery Action The Timeswitch's memory elements could be faulty. Run the Timeswitch Memory Diagnostic, and then re-run the diagnostic which failed to further test the behavior of the Timeswitch.

Technical Support Action The Timeswitch's memory elements could be faulty. Run the Timeswitch Memory Diagnostic, and then re-run the diagnostic which failed to further test the behavior of the Timeswitch.

 

Event Code: 37426

Severity Critical

Description The Diagnostic failed to remove a connection between two channels on the indicated Board's fourth DSP. Timeswitch software returned an error for a "Disconnect" request.

Impact The Timeswitch's memory elements could be faulty. Call processing using the indicated Board's first could be greatly impacted.

Recovery Action The Timeswitch's memory elements could be faulty. Run the Timeswitch Memory Diagnostic, and then re-run the diagnostic which failed to further test the behavior of the Timeswitch.

Technical Support Action The Timeswitch's memory elements could be faulty. Run the Timeswitch Memory Diagnostic, and then re-run the diagnostic which failed to further test the behavior of the Timeswitch.

 

Event Code: 37427

Severity Critical

Description The Diagnostic failed to remove a connection between two channels on the indicated Board's fifth DSP. Timeswitch software returned an error for a "Disconnect" request.

Impact The Timeswitch's memory elements could be faulty. Call processing using the indicated Board's first could be greatly impacted.

Recovery Action The Timeswitch's memory elements could be faulty. Run the Timeswitch Memory Diagnostic, and then re-run the diagnostic which failed to further test the behavior of the Timeswitch.

Technical Support Action The Timeswitch's memory elements could be faulty. Run the Timeswitch Memory Diagnostic, and then re-run the diagnostic which failed to further test the behavior of the Timeswitch.

 

Event Code: 37428

Severity Critical

Description The Diagnostic failed to remove a connection between two channels on the indicated Board's sixth DSP. Timeswitch software returned an error for a "Disconnect" request.

Impact The Timeswitch's memory elements could be faulty. Call processing using the indicated Board's first could be greatly impacted.

Recovery Action The Timeswitch's memory elements could be faulty. Run the Timeswitch Memory Diagnostic, and then re-run the diagnostic which failed to further test the behavior of the Timeswitch.

Technical Support Action The Timeswitch's memory elements could be faulty. Run the Timeswitch Memory Diagnostic, and then re-run the diagnostic which failed to further test the behavior of the Timeswitch.

 

Event Code: 37429

Severity Critical

Description The Diagnostic failed to enable Board #1's Timeswitch. Timeswitch software returned an error in response to an "Enable" request.

Impact The Timeswitch's memory elements could be faulty. Call processing using the indicated Board's first could be greatly impacted.

Recovery Action Board #1's Timeswitch memory elements could be faulty. Run the Timeswitch Memory Diagnostic to further test the behaviour of the Timeswitch.

Technical Support Action Board #1's Timeswitch memory elements could be faulty. Run the Timeswitch Memory Diagnostic to further test the behaviour of the Timeswitch.

 

Event Code: 37430

Severity Critical

Description The Diagnostic failed to enable Board #2's Timeswitch. Timeswitch software returned an error in response to an "Enable" request.

Impact The Timeswitch's memory elements could be faulty. Call processing using the indicated Board's first could be greatly impacted.

Recovery Action Board #2's Timeswitch memory elements could be faulty. Run the Timeswitch Memory Diagnostic to further test the behaviour of the Timeswitch.

Technical Support Action Board #2's Timeswitch memory elements could be faulty. Run the Timeswitch Memory Diagnostic to further test the behaviour of the Timeswitch.

 

Event Code: 37431

Severity Critical

Description The Diagnostic failed to enable Board #3's Timeswitch. Timeswitch software returned an error in response to an "Enable" request.

Impact The Timeswitch's memory elements could be faulty. Call processing using the indicated Board's first could be greatly impacted.

Recovery Action Board #3's Timeswitch memory elements could be faulty. Run the Timeswitch Memory Diagnostic to further test the behaviour of the Timeswitch.

Technical Support Action Board #3's Timeswitch memory elements could be faulty. Run the Timeswitch Memory Diagnostic to further test the behaviour of the Timeswitch.

 

Event Code: 37432

Severity Critical

Description The Diagnostic failed to enable Board #4's Timeswitch. Timeswitch software returned an error in response to an "Enable" request.

Impact The Timeswitch's memory elements could be faulty. Call processing using the indicated Board's first could be greatly impacted.

Recovery Action Board #4's Timeswitch memory elements could be faulty. Run the Timeswitch Memory Diagnostic to further test the behaviour of the Timeswitch.

Technical Support Action Board #4's Timeswitch memory elements could be faulty. Run the Timeswitch Memory Diagnostic to further test the behaviour of the Timeswitch.

 

Event Code: 37433

Severity Critical

Description The Diagnostic failed to enable Board #5's Timeswitch. Timeswitch software returned an error in response to an "Enable" request.

Impact The Timeswitch's memory elements could be faulty. Call processing using the indicated Board's first could be greatly impacted.

Recovery Action Board #5's Timeswitch memory elements could be faulty. Run the Timeswitch Memory Diagnostic to further test the behaviour of the Timeswitch.

Technical Support Action Board #5's Timeswitch memory elements could be faulty. Run the Timeswitch Memory Diagnostic to further test the behaviour of the Timeswitch.

 

Event Code: 37434

Severity Critical

Description The Diagnostic failed to disable Board #1's Timeswitch. Timeswitch software returned an error in response to a "Disable" request.

Impact The Timeswitch's memory elements could be faulty. Call processing using the indicated Board's first could be greatly impacted.

Recovery Action Board #1's Timeswitch memory elements could be faulty. Run the Timeswitch Memory Diagnostic to further test the behaviour of the Timeswitch.

Technical Support Action Board #1's Timeswitch memory elements could be faulty. Run the Timeswitch Memory Diagnostic to further test the behaviour of the Timeswitch.

 

Event Code: 37435

Severity Critical

Description The Diagnostic failed to disable Board #2's Timeswitch. Timeswitch software returned an error in response to an "Disable" request.

Impact The Timeswitch's memory elements could be faulty. Call processing using the indicated Board's first could be greatly impacted.

Recovery Action Board #2's Timeswitch memory elements could be faulty. Run the Timeswitch Memory Diagnostic to further test the behaviour of the Timeswitch.

Technical Support Action Board #2's Timeswitch memory elements could be faulty. Run the Timeswitch Memory Diagnostic to further test the behaviour of the Timeswitch.

 

Event Code: 37436

Severity Critical

Description The Diagnostic failed to disable Board #3's Timeswitch. Timeswitch software returned an error in response to a "Disable" request.

Impact The Timeswitch's memory elements could be faulty. Call processing using the indicated Board's first could be greatly impacted.

Recovery Action Board #3's Timeswitch memory elements could be faulty. Run the Timeswitch Memory Diagnostic to further test the behaviour of the Timeswitch.

Technical Support Action Board #3's Timeswitch memory elements could be faulty. Run the Timeswitch Memory Diagnostic to further test the behaviour of the Timeswitch.

 

Event Code: 37437

Severity Critical

Description The Diagnostic failed to disable Board #4's Timeswitch. Timeswitch software returned an error in response to a "Disable" request.

Impact The Timeswitch's memory elements could be faulty. Call processing using the indicated Board's first could be greatly impacted.

Recovery Action Board #4's Timeswitch memory elements could be faulty. Run the Timeswitch Memory Diagnostic to further test the behaviour of the Timeswitch.

Technical Support Action Board #4's Timeswitch memory elements could be faulty. Run the Timeswitch Memory Diagnostic to further test the behaviour of the Timeswitch.

 

Event Code: 37438

Severity Critical

Description The Diagnostic failed to disable Board #5's Timeswitch. Timeswitch software returned an error in response to a "Disable" request.

Impact The Timeswitch's memory elements could be faulty. Call processing using the indicated Board's first could be greatly impacted.

Recovery Action Board #5's Timeswitch memory elements could be faulty. Run the Timeswitch Memory Diagnostic to further test the behaviour of the Timeswitch.

Technical Support Action Board #5's Timeswitch memory elements could be faulty. Run the Timeswitch Memory Diagnostic to further test the behaviour of the Timeswitch.

 

Event Code: 37439

Severity Critical

Description The Timeswitch Memory Diagnostic test on Board #1's Timeswitch failed. The Diagnostic was unable to write to the Timeswitch's TAP memory.

Impact The Timeswitch's memory elements could be faulty. Call processing using Board #1 could be greatly impacted.

Recovery Action The Timeswitch memory elements on Board #1 could be faulty. Repeat the test to confirm the failure.

Technical Support Action The Timeswitch memory elements on Board #1 could be faulty. Repeat the test to confirm the failure. If the failure persists then the Timeswitch on Board #1 will require a replacement switch.

 

Event Code: 37440

Severity Critical

Description The Timeswitch Memory Diagnostic test on Board #2's Timeswitch failed. The Diagnostic was unable to write to the Timeswitch's TAP memory.

Impact The Timeswitch's memory elements could be faulty. Call processing using Board #2 could be greatly impacted.

Recovery Action The Timeswitch memory elements on Board #2 could be faulty. Repeat the test to confirm the failure.

Technical Support Action The Timeswitch memory elements on Board #2 could be faulty. Repeat the test to confirm the failure. If the failure persists then the Timeswitch on Board #2 will require replacement.

 

Event Code: 37441

Severity Critical

Description The Timeswitch Memory Diagnostic test on Board #3's Timeswitch failed. The Diagnostic was unable to write to the Timeswitch's TAP memory.

Impact The Timeswitch's memory elements could be faulty. Call processing using Board #3 could be greatly impacted.

Recovery Action The Timeswitch memory elements on Board #3 could be faulty. Repeat the test to confirm the failure.

Technical Support Action The Timeswitch memory elements on Board #3 could be faulty. Repeat the test to confirm the failure. If the failure persists then the Timeswitch on Board #3 will require replacement.

 

Event Code: 37442

Severity Critical

Description The Timeswitch Memory Diagnostic test on Board #4's Timeswitch failed. The Diagnostic was unable to write to the Timeswitch's TAP memory.

Impact The Timeswitch's memory elements could be faulty. Call processing using Board #4 could be greatly impacted.

Recovery Action The Timeswitch memory elements on Board #4 could be faulty. Repeat the test to confirm the failure.

Technical Support Action The Timeswitch memory elements on Board #4 could be faulty. Repeat the test to confirm the failure. If the failure persists then the Timeswitch on Board #4 will require replacement.

 

Event Code: 37443

Severity Critical

Description The Timeswitch Memory Diagnostic test on Board #5's Timeswitch failed. The Diagnostic was unable to write to the Timeswitch's TAP memory.

Impact The Timeswitch's memory elements could be faulty. Call processing using Board #5 could be greatly impacted.

Recovery Action The Timeswitch memory elements on Board #5 could be faulty. Repeat the test to confirm the failure.

Technical Support Action The Timeswitch memory elements on Board #5 could be faulty. Repeat the test to confirm the failure. If the failure persists then the Timeswitch on Board #5 will require replacement.

 

Event Code: 37444

Severity Critical

Description The Diagnostic test on Board #1's Timeswitch failed. The Diagnostic was unable to write to the Timeswitch's UNUSED TAP memory.

Impact The Timeswitch's memory elements could be faulty. Call processing using Board #1 could be greatly impacted.

Recovery Action The Timeswitch memory elements on Board #1 could be faulty. Run the Timeswitch Memory Diagnostic to confirm the result.

Technical Support Action The Timeswitch memory elements on Board #1 could be faulty. Run the Timeswitch Memory Diagnostic to confirm the result. If the failure persists then the Timeswitch on Board #1 will require replacement.

 

Event Code: 37445

Severity Critical

Description The Diagnostic test on Board #2's Timeswitch failed. The Diagnostic was unable to write to the Timeswitch's UNUSED TAP memory.

Impact The Timeswitch's memory elements could be faulty. Call processing using Board #2 could be greatly impacted.

Recovery Action The Timeswitch memory elements on Board #2 could be faulty. Run the Timeswitch Memory Diagnostic to confirm the result.

Technical Support Action The Timeswitch memory elements on Board #2 could be faulty. Run the Timeswitch Memory Diagnostic to confirm the result. If the failure persists then the Timeswitch on Board #2 will require replacement.

 

Event Code: 37446

Severity Critical

Description The Diagnostic test on Board #3's Timeswitch failed. The Diagnostic was unable to write to the Timeswitch's UNUSED TAP memory.

Impact The Timeswitch's memory elements could be faulty. Call processing using Board #3 could be greatly impacted.

Recovery Action The Timeswitch memory elements on Board #3 could be faulty. Run the Timeswitch Memory Diagnostic to confirm the result.

Technical Support Action The Timeswitch memory elements on Board #3 could be faulty. Run the Timeswitch Memory Diagnostic to confirm the result. If the failure persists then the Timeswitch on Board #3 will require replacement.

 

Event Code: 37447

Severity Critical

Description The Diagnostic test on Board #4's Timeswitch failed. The Diagnostic was unable to write to the Timeswitch's UNUSED TAP memory.

Impact The Timeswitch's memory elements could be faulty. Call processing using Board #4 could be greatly impacted.

Recovery Action The Timeswitch memory elements on Board #4 could be faulty. Run the Timeswitch Memory Diagnostic to confirm the result.

Technical Support Action The Timeswitch memory elements on Board #4 could be faulty. Run the Timeswitch Memory Diagnostic to confirm the result. If the failure persists then the Timeswitch on Board #4 will require replacement.

 

Event Code: 37448

Severity Critical

Description The Diagnostic test on Board #5's Timeswitch failed. The Diagnostic was unable to write to the Timeswitch's UNUSED TAP memory.

Impact The Timeswitch's memory elements could be faulty. Call processing using Board #5 could be greatly impacted.

Recovery Action The Timeswitch memory elements on Board #5 could be faulty. Run the Timeswitch Memory Diagnostic to confirm the result.

Technical Support Action The Timeswitch memory elements on Board #5 could be faulty. Run the Timeswitch Memory Diagnostic to confirm the result. If the failure persists then the Timeswitch on Board #5 will require replacement.

 

Event Code: 37449

Severity Critical

Description The Diagnostic test on Board #1's Timeswitch failed. The Diagnostic was unable to write to the Timeswitch's CONNECTION memory.

Impact The Timeswitch's memory elements could be faulty. Call processing using Board #1 could be greatly impacted.

Recovery Action The Timeswitch memory elements on Board #1 could be faulty. Run the Timeswitch Memory Diagnostic to confirm the result.

Technical Support Action The Timeswitch memory elements on Board #1 could be faulty. Run the Timeswitch Memory Diagnostic to confirm the result. If the failure persists then the Timeswitch on Board #1 will require replacement.

 

Event Code: 37450

Severity Critical

Description The Diagnostic test on Board #2's Timeswitch failed. The Diagnostic was unable to write to the Timeswitch's CONNECTION memory.

Impact The Timeswitch's memory elements could be faulty. Call processing using Board #2 could be greatly impacted.

Recovery Action The Timeswitch memory elements on Board #2 could be faulty. Run the Timeswitch Memory Diagnostic to confirm the result.

Technical Support Action The Timeswitch memory elements on Board #2 could be faulty. Run the Timeswitch Memory Diagnostic to confirm the result. If the failure persists then the Timeswitch on Board #2 will require replacement.

 

Event Code: 37451

Severity Critical

Description The Diagnostic test on Board #3's Timeswitch failed. The Diagnostic was unable to write to the Timeswitch's CONNECTION memory.

Impact The Timeswitch's memory elements could be faulty. Call processing using Board #3 could be greatly impacted.

Recovery Action The Timeswitch memory elements on Board #3 could be faulty. Run the Timeswitch Memory Diagnostic to confirm the result.

Technical Support Action The Timeswitch memory elements on Board #3 could be faulty. Run the Timeswitch Memory Diagnostic to confirm the result. If the failure persists then the Timeswitch on Board #3 will require replacement.

 

Event Code: 37452

Severity Critical

Description The Diagnostic test on Board #4's Timeswitch failed. The Diagnostic was unable to write to the Timeswitch's CONNECTION memory.

Impact The Timeswitch's memory elements could be faulty. Call processing using Board #4 could be greatly impacted.

Recovery Action The Timeswitch memory elements on Board #4 could be faulty. Run the Timeswitch Memory Diagnostic to confirm the result.

Technical Support Action The Timeswitch memory elements on Board #4 could be faulty. Run the Timeswitch Memory Diagnostic to confirm the result. If the failure persists then the Timeswitch on Board #4 will require replacement.

 

Event Code: 37453

Severity Critical

Description The Diagnostic test on Board #5's Timeswitch failed. The Diagnostic was unable to write to the Timeswitch's CONNECTION memory.

Impact The Timeswitch's memory elements could be faulty. Call processing using Board #5 could be greatly impacted.

Recovery Action The Timeswitch memory elements on Board #5 could be faulty. Run the Timeswitch Memory Diagnostic to confirm the result.

Technical Support Action The Timeswitch memory elements on Board #5 could be faulty. Run the Timeswitch Memory Diagnostic to confirm the result. If the failure persists then the Timeswitch on Board #5 will require replacement.

 

Event Code: 37454

Severity Critical

Description The Diagnostic test on Board #1's Timeswitch failed. The Diagnostic was unable to read from the Timeswitch's TAP memory.

Impact The Timeswitch's memory elements could be faulty. Call processing using Board #1 could be greatly impacted.

Recovery Action The Timeswitch memory elements on Board #1 could be faulty. Run the Timeswitch Memory Diagnostic to confirm the result.

Technical Support Action The Timeswitch memory elements on Board #1 could be faulty. Run the Timeswitch Memory Diagnostic to confirm the result. If the failure persists then the Timeswitch on Board #1 will require replacement.

 

Event Code: 37455

Severity Critical

Description The Diagnostic test on Board #2's Timeswitch failed. The Diagnostic was unable to read from the Timeswitch's TAP memory.

Impact The Timeswitch's memory elements could be faulty. Call processing using Board #2 could be greatly impacted.

Recovery Action The Timeswitch memory elements on Board #2 could be faulty. Run the Timeswitch Memory Diagnostic to confirm the result.

Technical Support Action The Timeswitch memory elements on Board #2 could be faulty. Run the Timeswitch Memory Diagnostic to confirm the result. If the failure persists then the Timeswitch on Board #2 will require replacement.

 

Event Code: 37456

Severity Critical

Description The Diagnostic test on Board #3's Timeswitch failed. The Diagnostic was unable to read from the Timeswitch's TAP memory.

Impact The Timeswitch's memory elements could be faulty. Call processing using Board #3 could be greatly impacted.

Recovery Action The Timeswitch memory elements on Board #3 could be faulty. Run the Timeswitch Memory Diagnostic to confirm the result.

Technical Support Action The Timeswitch memory elements on Board #3 could be faulty. Run the Timeswitch Memory Diagnostic to confirm the result. If the failure persists then the Timeswitch on Board #3 will require replacement.

 

Event Code: 37457

Severity Critical

Description The Diagnostic test on Board #4's Timeswitch failed. The Diagnostic was unable to read from the Timeswitch's TAP memory.

Impact The Timeswitch's memory elements could be faulty. Call processing using Board #4 could be greatly impacted.

Recovery Action The Timeswitch memory elements on Board #4 could be faulty. Run the Timeswitch Memory Diagnostic to confirm the result.

Technical Support Action The Timeswitch memory elements on Board #4 could be faulty. Run the Timeswitch Memory Diagnostic to confirm the result. If the failure persists then the Timeswitch on Board #4 will require replacement.

 

Event Code: 37458

Severity Critical

Description The Diagnostic test on Board #5's Timeswitch failed. The Diagnostic was unable to read from the Timeswitch's TAP memory.

Impact The Timeswitch's memory elements could be faulty. Call processing using Board #5 could be greatly impacted.

Recovery Action The Timeswitch memory elements on Board #5 could be faulty. Run the Timeswitch Memory Diagnostic to confirm the result.

Technical Support Action The Timeswitch memory elements on Board #5 could be faulty. Run the Timeswitch Memory Diagnostic to confirm the result. If the failure persists then the Timeswitch on Board #5 will require replacement.

 

Event Code: 37459

Severity Critical

Description The Timeswitch Memory Diagnostic test on Board #1's Timeswitch failed. The Diagnostic was unable to read from the Timeswitch's CONNECTION memory.

Impact The Timeswitch's memory elements could be faulty. Call processing using Board #1 could be greatly impacted.

Recovery Action The Timeswitch memory elements on Board #1 could be faulty. Repeat the test to confirm the failure.

Technical Support Action The Timeswitch memory elements on Board #1 could be faulty. Repeat the test to confirm the failure. If the failure persists then the Timeswitch on Board #1 will require replacement.

 

Event Code: 37460

Severity Critical

Description The Timeswitch Memory Diagnostic test on Board #2's Timeswitch failed. The Diagnostic was unable to read from the Timeswitch's CONNECTION memory.

Impact The Timeswitch's memory elements could be faulty. Call processing using Board #2 could be greatly impacted.

Recovery Action The Timeswitch memory elements on Board #2 could be faulty. Repeat the test to confirm the failure.

Technical Support Action The Timeswitch memory elements on Board #2 could be faulty. Repeat the test to confirm the failure. If the failure persists then the Timeswitch on Board #2 will require replacement.

 

Event Code: 37461

Severity Critical

Description The Timeswitch Memory Diagnostic test on Board #3's Timeswitch failed. The Diagnostic was unable to read from the Timeswitch's CONNECTION memory.

Impact The Timeswitch's memory elements could be faulty. Call processing using Board #3 could be greatly impacted.

Recovery Action The Timeswitch memory elements on Board #3 could be faulty. Repeat the test to confirm the failure.

Technical Support Action The Timeswitch memory elements on Board #3 could be faulty. Repeat the test to confirm the failure. If the failure persists then the Timeswitch on Board #3 will require replacement.

 

Event Code: 37462

Severity Critical

Description The Timeswitch Memory Diagnostic test on Board #4's Timeswitch failed. The Diagnostic was unable to read from the Timeswitch's CONNECTION memory.

Impact The Timeswitch's memory elements could be faulty. Call processing using Board #4 could be greatly impacted.

Recovery Action The Timeswitch memory elements on Board #4 could be faulty. Repeat the test to confirm the failure.

Technical Support Action The Timeswitch memory elements on Board #4 could be faulty. Repeat the test to confirm the failure. If the failure persists then the Timeswitch on Board #4 will require replacement.

 

Event Code: 37463

Severity Critical

Description The Timeswitch Memory Diagnostic test on Board #5's Timeswitch failed. The Diagnostic was unable to read from the Timeswitch's CONNECTION memory.

Impact The Timeswitch's memory elements could be faulty. Call processing using Board #5 could be greatly impacted.

Recovery Action The Timeswitch memory elements on Board #5 could be faulty. Repeat the test to confirm the failure.

Technical Support Action The Timeswitch memory elements on Board #5 could be faulty. Repeat the test to confirm the failure. If the failure persists then the Timeswitch on Board #5 will require replacement.

 

Event Code: 37464

Severity Critical

Description The Timeswitch Memory Diagnostic test on Board #1's Timeswitch failed. The Diagnostic was unable to read from the Timeswitch's UNUSED TAP memory.

Impact The Timeswitch's memory elements could be faulty. Call processing using Board #1 could be greatly impacted.

Recovery Action The Timeswitch memory elements on Board #1 could be faulty. Repeat the test to confirm the failure.

Technical Support Action The Timeswitch memory elements on Board #1 could be faulty. Repeat the test to confirm the failure. If the failure persists then the Timeswitch on Board #1 will require replacement.

 

Event Code: 37465

Severity Critical

Description The Timeswitch Memory Diagnostic test on Board #2's Timeswitch failed. The Diagnostic was unable to read from the Timeswitch's UNUSED TAP memory.

Impact The Timeswitch's memory elements could be faulty. Call processing using Board #2 could be greatly impacted.

Recovery Action The Timeswitch memory elements on Board #2 could be faulty. Repeat the test to confirm the failure.

Technical Support Action The Timeswitch memory elements on Board #2 could be faulty. Repeat the test to confirm the failure. If the failure persists then the Timeswitch on Board #2 will require replacement.

 

Event Code: 37466

Severity Critical

Description The Timeswitch Memory Diagnostic test on Board #3's Timeswitch failed. The Diagnostic was unable to read from the Timeswitch's UNUSED TAP memory.

Impact The Timeswitch's memory elements could be faulty. Call processing using Board #3 could be greatly impacted.

Recovery Action The Timeswitch memory elements on Board #3 could be faulty. Repeat the test to confirm the failure.

Technical Support Action The Timeswitch memory elements on Board #3 could be faulty. Repeat the test to confirm the failure. If the failure persists then the Timeswitch on Board #3 will require replacement.

 

Event Code: 37467

Severity Critical

Description The Timeswitch Memory Diagnostic test on Board #4's Timeswitch failed. The Diagnostic was unable to read from the Timeswitch's UNUSED TAP memory.

Impact The Timeswitch's memory elements could be faulty. Call processing using Board #4 could be greatly impacted.

Recovery Action The Timeswitch memory elements on Board #4 could be faulty. Repeat the test to confirm the failure.

Technical Support Action The Timeswitch memory elements on Board #4 could be faulty. Repeat the test to confirm the failure. If the failure persists then the Timeswitch on Board #4 will require replacement.

 

Event Code: 37468

Severity Critical

Description The Timeswitch Memory Diagnostic test on Board #5's Timeswitch failed. The Diagnostic was unable to read from the Timeswitch's UNUSED TAP memory.

Impact The Timeswitch's memory elements could be faulty. Call processing using Board #5 could be greatly impacted.

Recovery Action The Timeswitch memory elements on Board #5 could be faulty. Repeat the test to confirm the failure.

Technical Support Action The Timeswitch memory elements on Board #5 could be faulty. Repeat the test to confirm the failure. If the failure persists then the Timeswitch on Board #5 will require replacement.

 

Event Code: 37469

Severity Major

Description The Timeswitch Local Loop-Back Diagnostic can only be run on platforms that contain an SCBUS Cable. IPE platforms do not possess an SCBUS cable.

Impact The Local Loop-Back Diagnostic will not function as expected.

Recovery Action Do not attempt to invoke the Timeswitch Local Loop-Back Diagnostic on IPE platforms.

Technical Support Action Do not attempt to invoke the Timeswitch Local Loop-Back Diagnostic on IPE platforms.

 

Event Code: 37470

Severity Major

Description The indicated Board's first DSP device could not be reset.

Impact The DSP might not be present or might be defective. The DSP can not be used for call processing and must be disabled.

Recovery Action The DSP might be defective. Confirm the results of the diagnostic by running the DSP Diagnostics.

Technical Support Action Ensure that the indicated DSP is properly plugged in if it is a PCMCIA DSP. Using Microsoft's "Windows NT Diagnostics" utility to ensure that the "ntbus.sys" and "c52.sys" device drivers are installed and that the indicated DSP device was created.

 

Event Code: 37471

Severity Major

Description The indicated Board's second DSP device could not be reset.

Impact The DSP might not be present or might be defective. The DSP can not be used for call processing and must be disabled.

Recovery Action The DSP might be defective. Confirm the results of the diagnostic by running the DSP Diagnostics.

Technical Support Action Ensure that the indicated DSP is properly plugged in if it is a PCMCIA DSP. Using Microsoft's "Windows NT Diagnostics" utility to ensure that the "ntbus.sys" and "c52.sys" device drivers are installed and that the indicated DSP device was created.

 

Event Code: 37472

Severity Major

Description The indicated Board's third DSP device could not be reset.

Impact The DSP might not be present or might be defective. The DSP can not be used for call processing and must be disabled.

Recovery Action The DSP might be defective. Confirm the results of the diagnostic by running the DSP Diagnostics.

Technical Support Action Ensure that the indicated DSP is properly plugged in if it is a PCMCIA DSP. Using Microsoft's "Windows NT Diagnostics" utility to ensure that the "ntbus.sys" and "c52.sys" device drivers are installed and that the indicated DSP device was created.

 

Event Code: 37473

Severity Major

Description The indicated Board's fourth DSP device could not be reset.

Impact The DSP might not be present or might be defective. The DSP can not be used for call processing and must be disabled.

Recovery Action The DSP might be defective. Confirm the results of the diagnostic by running the DSP Diagnostics.

Technical Support Action Ensure that the indicated DSP is properly plugged in if it is a PCMCIA DSP. Using Microsoft's "Windows NT Diagnostics" utility to ensure that the "ntbus.sys" and "c52.sys" device drivers are installed and that the indicated DSP device was created.

 

Event Code: 37474

Severity Major

Description The indicated Board's fifth DSP device could not be reset.

Impact The DSP might not be present or might be defective. The DSP can not be used for call processing and must be disabled.

Recovery Action The DSP might be defective. Confirm the results of the diagnostic by running the DSP Diagnostics.

Technical Support Action Ensure that the indicated DSP is properly plugged in if it is a PCMCIA DSP. Using Microsoft's "Windows NT Diagnostics" utility to ensure that the "ntbus.sys" and "c52.sys" device drivers are installed and that the indicated DSP device was created.

 

Event Code: 37475

Severity Major

Description The indicated Board's sixth DSP device could not be reset.

Impact The DSP might not be present or might be defective. The DSP can not be used for call processing and must be disabled.

Recovery Action The DSP might be defective. Confirm the results of the diagnostic by running the DSP Diagnostics.

Technical Support Action Ensure that the indicated DSP is properly plugged in if it is a PCMCIA DSP. Using Microsoft's "Windows NT Diagnostics" utility to ensure that the "ntbus.sys" and "c52.sys" device drivers are installed and that the indicated DSP device was created.

 

Event Code: 37496

Severity Major

Description The Timeswitch CLI Diagnostic Tool failed to allocate memory.

Impact Overall system performance will be very slow. The selected diagnostic will not be run.

Recovery Action Please contact your technical support organization.

Technical Support Action Please contact your technical support organization.

 

Event Code: 37497

Severity Major

Description A call to "nbdsp.dll" - Nbdsp_GetInstalledDSPs failed.

Impact The installed DSP(s) might be defective and call processing may be severely impacted.

Recovery Action Ensure that the "ntbus.sys" and "c52.sys" device drivers have been started by viewing the contents of the "Devices" applet in the Windows NT Control Panel Group. Please contact your technical support organization.

Technical Support Action Ensure that all DSPs are properly plugged in if they are PCMCIA DSPs. Using Microsoft's "Windows NT Diagnostics" utility to ensure that the "ntbus.sys" and "c52.sys" device drivers are installed and that the indicated DSP device was created.

 

Event Code: 37498

Severity Critical

Description No devices that can be tested are installed on the system (No SCBUSes, NTBUSes, or DSPs).

Impact There are no SCBUSes, NTBUSes, or DSPs installed in the system - call processing might be severely impacted.

Recovery Action Ensure that the "ntbus.sys" and "c52.sys" device drivers have been started by viewing the contents of the "Devices" applet in the Windows NT Control Panel Group. Please contact your technical support organization.

Technical Support Action Ensure that all hardware is properly installed in the system. Also ensure that the "ntbus.sys" and "c52.sys" device drivers have been started by viewing the contents of the "Devices" applet in the Windows NT Control Panel Group.

 

Event Code: 37499

Severity Minor

Description An impossible code path was reached.

Impact The Timeswitch CLI Diagnostic Tool (nbtswdgn.exe) will not function as expected.

Recovery Action A software error occurred while executing the diagnostic. Please contact your technical support organization.

Technical Support Action A software error occurred while executing the diagnostic. Please contact your technical support organization.