Severity Critical
Description The Diagnostic could not read from SRAM memory of the indicated Board's second DSP.
Impact The DSP's memory elements could be faulty. The DSP may not be able to be used for call processing.
Recovery Action The DSP's on-board memory elements could be defective. Run the DSP Diagnostics to confirm the result of the diagnostic. Please contact your technical support organization for additional instructions.
Technical Support Action The DSP's on-board memory elements could be defective. Run the DSP Diagnostics to confirm that the DSP is defective. Try replacing the DSP with one that is known to function correctly and re-run the diagnostic.
Severity Critical
Description The Diagnostic could not read from SRAM memory of the indicated Board's third DSP.
Impact The DSP's memory elements could be faulty. The DSP may not be able to be used for call processing.
Recovery Action The DSP's on-board memory elements could be defective. Run the DSP Diagnostics to confirm the result of the diagnostic. Please contact your technical support organization for additional instructions.
Technical Support Action The DSP's on-board memory elements could be defective. Run the DSP Diagnostics to confirm that the DSP is defective. Try replacing the DSP with one that is known to function correctly and re-run the diagnostic.
Severity Critical
Description The Diagnostic could not read from SRAM memory of the indicated Board's fourth DSP.
Impact The DSP's memory elements could be faulty. The DSP may not be able to be used for call processing.
Recovery Action The DSP's on-board memory elements could be defective. Run the DSP Diagnostics to confirm the result of the diagnostic. Please contact your technical support organization for additional instructions.
Technical Support Action The DSP's on-board memory elements could be defective. Run the DSP Diagnostics to confirm that the DSP is defective. Try replacing the DSP with one that is known to function correctly and re-run the diagnostic.
Severity Critical
Description The Diagnostic could not read from SRAM memory of the indicated Board's fifth DSP.
Impact The DSP's memory elements could be faulty. The DSP may not be able to be used for call processing.
Recovery Action The DSP's on-board memory elements could be defective. Run the DSP Diagnostics to confirm the result of the diagnostic. Please contact your technical support organization for additional instructions.
Technical Support Action The DSP's on-board memory elements could be defective. Run the DSP Diagnostics to confirm that the DSP is defective. Try replacing the DSP with one that is known to function correctly and re-run the diagnostic.
Severity Critical
Description The Diagnostic could not read from SRAM memory of the indicated Board's sixth DSP.
Impact The DSP's memory elements could be faulty. The DSP may not be able to be used for call processing.
Recovery Action The DSP's on-board memory elements could be defective. Run the DSP Diagnostics to confirm the result of the diagnostic. Please contact your technical support organization for additional instructions.
Technical Support Action The DSP's on-board memory elements could be defective. Run the DSP Diagnostics to confirm that the DSP is defective. Try replacing the DSP with one that is known to function correctly and re-run the diagnostic.
Severity Critical
Description The Diagnostic could not write to SRAM memory of the indicated Board's first DSP.
Impact The DSP's memory elements could be faulty. The DSP may not be able to be used for call processing.
Recovery Action The DSP's on-board memory elements could be defective. Run the DSP Diagnostics to confirm the result of the diagnostic. Please contact your technical support organization for additional instructions.
Technical Support Action The DSP's on-board memory elements could be defective. Run the DSP Diagnostics to confirm that the DSP is defective. Try replacing the DSP with one that is known to function correctly and re-run the diagnostic.
Severity Critical
Description The Diagnostic could not write to SRAM memory of the indicated Board's second DSP.
Impact The DSP's memory elements could be faulty. The DSP may not be able to be used for call processing.
Recovery Action The DSP's on-board memory elements could be defective. Run the DSP Diagnostics to confirm the result of the diagnostic. Please contact your technical support organization for additional instructions.
Technical Support Action The DSP's on-board memory elements could be defective. Run the DSP Diagnostics to confirm that the DSP is defective. Try replacing the DSP with one that is known to function correctly and re-run the diagnostic.
Severity Critical
Description The Diagnostic could not write to SRAM memory of the indicated Board's third DSP.
Impact The DSP's memory elements could be faulty. The DSP may not be able to be used for call processing.
Recovery Action The DSP's on-board memory elements could be defective. Run the DSP Diagnostics to confirm the result of the diagnostic. Please contact your technical support organization for additional instructions.
Technical Support Action The DSP's on-board memory elements could be defective. Run the DSP Diagnostics to confirm that the DSP is defective. Try replacing the DSP with one that is known to function correctly and re-run the diagnostic.
Severity Critical
Description The Diagnostic could not write to SRAM memory of the indicated Board's fourth DSP.
Impact The DSP's memory elements could be faulty. The DSP may not be able to be used for call processing.
Recovery Action The DSP's on-board memory elements could be defective. Run the DSP Diagnostics to confirm the result of the diagnostic. Please contact your technical support organization for additional instructions.
Technical Support Action The DSP's on-board memory elements could be defective. Run the DSP Diagnostics to confirm that the DSP is defective. Try replacing the DSP with one that is known to function correctly and re-run the diagnostic.
Severity Critical
Description The Diagnostic could not write to SRAM memory of the indicated Board's fifth DSP.
Impact The DSP's memory elements could be faulty. The DSP may not be able to be used for call processing.
Recovery Action The DSP's on-board memory elements could be defective. Run the DSP Diagnostics to confirm the result of the diagnostic. Please contact your technical support organization for additional instructions.
Technical Support Action The DSP's on-board memory elements could be defective. Run the DSP Diagnostics to confirm that the DSP is defective. Try replacing the DSP with one that is known to function correctly and re-run the diagnostic.
Severity Critical
Description The Diagnostic could not write to SRAM memory of the indicated Board's sixth DSP.
Impact The DSP's memory elements could be faulty. The DSP may not be able to be used for call processing.
Recovery Action The DSP's on-board memory elements could be defective. Run the DSP Diagnostics to confirm the result of the diagnostic. Please contact your technical support organization for additional instructions.
Technical Support Action The DSP's on-board memory elements could be defective. Run the DSP Diagnostics to confirm that the DSP is defective. Try replacing the DSP with one that is known to function correctly and re-run the diagnostic.
Severity Critical
Description The Diagnostic could not write to I/O REGISTER memory of the indicated Board's first DSP.
Impact The DSP's memory elements could be faulty. The DSP may not be able to be used for call processing.
Recovery Action The DSP's on-board memory elements could be defective. Run the DSP Diagnostics to confirm the result of the diagnostic. Please contact your technical support organization for additional instructions.
Technical Support Action The DSP's on-board memory elements could be defective. Run the DSP Diagnostics to confirm that the DSP is defective. Try replacing the DSP with one that is known to function correctly and re-run the diagnostic.
Severity Critical
Description The Diagnostic could not write to I/O REGISTER memory of the indicated Board's second DSP.
Impact The DSP's memory elements could be faulty. The DSP may not be able to be used for call processing.
Recovery Action The DSP's on-board memory elements could be defective. Run the DSP Diagnostics to confirm the result of the diagnostic. Please contact your technical support organization for additional instructions.
Technical Support Action The DSP's on-board memory elements could be defective. Run the DSP Diagnostics to confirm that the DSP is defective. Try replacing the DSP with one that is known to function correctly and re-run the diagnostic.
Severity Critical
Description The Diagnostic could not write to I/O REGISTER memory of the indicated Board's third DSP.
Impact The DSP's memory elements could be faulty. The DSP may not be able to be used for call processing.
Recovery Action The DSP's on-board memory elements could be defective. Run the DSP Diagnostics to confirm the result of the diagnostic. Please contact your technical support organization for additional instructions.
Technical Support Action The DSP's on-board memory elements could be defective. Run the DSP Diagnostics to confirm that the DSP is defective. Try replacing the DSP with one that is known to function correctly and re-run the diagnostic.
Severity Critical
Description The Diagnostic could not write to I/O REGISTER memory of the indicated Board's fourth DSP.
Impact The DSP's memory elements could be faulty. The DSP may not be able to be used for call processing.
Recovery Action The DSP's on-board memory elements could be defective. Run the DSP Diagnostics to confirm the result of the diagnostic. Please contact your technical support organization for additional instructions.
Technical Support Action The DSP's on-board memory elements could be defective. Run the DSP Diagnostics to confirm that the DSP is defective. Try replacing the DSP with one that is known to function correctly and re-run the diagnostic.
Severity Critical
Description The Diagnostic could not write to I/O REGISTER memory of the indicated Board's fifth DSP.
Impact The DSP's memory elements could be faulty. The DSP may not be able to be used for call processing.
Recovery Action The DSP's on-board memory elements could be defective. Run the DSP Diagnostics to confirm the result of the diagnostic. Please contact your technical support organization for additional instructions.
Technical Support Action The DSP's on-board memory elements could be defective. Run the DSP Diagnostics to confirm that the DSP is defective. Try replacing the DSP with one that is known to function correctly and re-run the diagnostic.
Severity Critical
Description The Diagnostic could not write to I/O REGISTER memory of the indicated Board's sixth DSP.
Impact The DSP's memory elements could be faulty. The DSP may not be able to be used for call processing.
Recovery Action The DSP's on-board memory elements could be defective. Run the DSP Diagnostics to confirm the result of the diagnostic. Please contact your technical support organization for additional instructions.
Technical Support Action The DSP's on-board memory elements could be defective. Run the DSP Diagnostics to confirm that the DSP is defective. Try replacing the DSP with one that is known to function correctly and re-run the diagnostic.
Severity Critical
Description The Diagnostic failed to form a connection between two channels on the indicated Board's first DSP. Timeswitch software returned an error for a "Connect" request.
Impact The Timeswitch's memory elements could be faulty. Call processing using the indicated Board's first could be greatly impacted.
Recovery Action The Timeswitch's memory elements could be faulty. Run the Timeswitch Memory Diagnostic, and then re-run the diagnostic which failed to further test the behavior of the Timeswitch.
Technical Support Action The Timeswitch's memory elements could be faulty. Run the Timeswitch Memory Diagnostic, and then re-run the diagnostic which failed to further test the behavior of the Timeswitch.
Severity Critical
Description The Diagnostic failed to form a connection between two channels on the indicated Board's second DSP. Timeswitch software returned an error for a "Connect" request.
Impact The Timeswitch's memory elements could be faulty. Call processing using the indicated Board's first could be greatly impacted.
Recovery Action The Timeswitch's memory elements could be faulty. Run the Timeswitch Memory Diagnostic, and then re-run the diagnostic which failed to further test the behavior of the Timeswitch.
Technical Support Action The Timeswitch's memory elements could be faulty. Run the Timeswitch Memory Diagnostic, and then re-run the diagnostic which failed to further test the behavior of the Timeswitch.
Severity Critical
Description The Diagnostic failed to form a connection between two channels on the indicated Board's third DSP. Timeswitch software returned an error for a "Connect" request.
Impact The Timeswitch's memory elements could be faulty. Call processing using the indicated Board's first could be greatly impacted.
Recovery Action The Timeswitch's memory elements could be faulty. Run the Timeswitch Memory Diagnostic, and then re-run the diagnostic which failed to further test the behavior of the Timeswitch.
Technical Support Action The Timeswitch's memory elements could be faulty. Run the Timeswitch Memory Diagnostic, and then re-run the diagnostic which failed to further test the behavior of the Timeswitch.
Severity Critical
Description The Diagnostic failed to form a connection between two channels on the indicated Board's fourth DSP. Timeswitch software returned an error for a "Connect" request.
Impact The Timeswitch's memory elements could be faulty. Call processing using the indicated Board's first could be greatly impacted.
Recovery Action The Timeswitch's memory elements could be faulty. Run the Timeswitch Memory Diagnostic, and then re-run the diagnostic which failed to further test the behavior of the Timeswitch.
Technical Support Action The Timeswitch's memory elements could be faulty. Run the Timeswitch Memory Diagnostic, and then re-run the diagnostic which failed to further test the behavior of the Timeswitch.
Severity Critical
Description The Diagnostic failed to form a connection between two channels on the indicated Board's fifth DSP. Timeswitch software returned an error for a "Connect" request.
Impact The Timeswitch's memory elements could be faulty. Call processing using the indicated Board's first could be greatly impacted.
Recovery Action The Timeswitch's memory elements could be faulty. Run the Timeswitch Memory Diagnostic, and then re-run the diagnostic which failed to further test the behavior of the Timeswitch.
Technical Support Action The Timeswitch's memory elements could be faulty. Run the Timeswitch Memory Diagnostic, and then re-run the diagnostic which failed to further test the behavior of the Timeswitch.
Severity Critical
Description The Diagnostic failed to form a connection between two channels on the indicated Board's sixth DSP. Timeswitch software returned an error for a "Connect" request.
Impact The Timeswitch's memory elements could be faulty. Call processing using the indicated Board's first could be greatly impacted.
Recovery Action The Timeswitch's memory elements could be faulty. Run the Timeswitch Memory Diagnostic, and then re-run the diagnostic which failed to further test the behavior of the Timeswitch.
Technical Support Action The Timeswitch's memory elements could be faulty. Run the Timeswitch Memory Diagnostic, and then re-run the diagnostic which failed to further test the behavior of the Timeswitch.
Severity Critical
Description The Diagnostic failed to remove a connection between two channels on the indicated Board's first DSP. Timeswitch software returned an error for a "Disconnect" request.
Impact The Timeswitch's memory elements could be faulty. Call processing using the indicated Board's first could be greatly impacted.
Recovery Action The Timeswitch's memory elements could be faulty. Run the Timeswitch Memory Diagnostic, and then re-run the diagnostic which failed to further test the behavior of the Timeswitch.
Technical Support Action The Timeswitch's memory elements could be faulty. Run the Timeswitch Memory Diagnostic, and then re-run the diagnostic which failed to further test the behavior of the Timeswitch.
Severity Critical
Description The Diagnostic failed to remove a connection between two channels on the indicated Board's second DSP. Timeswitch software returned an error for a "Disconnect" request.
Impact The Timeswitch's memory elements could be faulty. Call processing using the indicated Board's first could be greatly impacted.
Recovery Action The Timeswitch's memory elements could be faulty. Run the Timeswitch Memory Diagnostic, and then re-run the diagnostic which failed to further test the behavior of the Timeswitch.
Technical Support Action The Timeswitch's memory elements could be faulty. Run the Timeswitch Memory Diagnostic, and then re-run the diagnostic which failed to further test the behavior of the Timeswitch.
Severity Critical
Description The Diagnostic failed to remove a connection between two channels on the indicated Board's third DSP. Timeswitch software returned an error for a "Disconnect" request.
Impact The Timeswitch's memory elements could be faulty. Call processing using the indicated Board's first could be greatly impacted.
Recovery Action The Timeswitch's memory elements could be faulty. Run the Timeswitch Memory Diagnostic, and then re-run the diagnostic which failed to further test the behavior of the Timeswitch.
Technical Support Action The Timeswitch's memory elements could be faulty. Run the Timeswitch Memory Diagnostic, and then re-run the diagnostic which failed to further test the behavior of the Timeswitch.
Severity Critical
Description The Diagnostic failed to remove a connection between two channels on the indicated Board's fourth DSP. Timeswitch software returned an error for a "Disconnect" request.
Impact The Timeswitch's memory elements could be faulty. Call processing using the indicated Board's first could be greatly impacted.
Recovery Action The Timeswitch's memory elements could be faulty. Run the Timeswitch Memory Diagnostic, and then re-run the diagnostic which failed to further test the behavior of the Timeswitch.
Technical Support Action The Timeswitch's memory elements could be faulty. Run the Timeswitch Memory Diagnostic, and then re-run the diagnostic which failed to further test the behavior of the Timeswitch.
Severity Critical
Description The Diagnostic failed to remove a connection between two channels on the indicated Board's fifth DSP. Timeswitch software returned an error for a "Disconnect" request.
Impact The Timeswitch's memory elements could be faulty. Call processing using the indicated Board's first could be greatly impacted.
Recovery Action The Timeswitch's memory elements could be faulty. Run the Timeswitch Memory Diagnostic, and then re-run the diagnostic which failed to further test the behavior of the Timeswitch.
Technical Support Action The Timeswitch's memory elements could be faulty. Run the Timeswitch Memory Diagnostic, and then re-run the diagnostic which failed to further test the behavior of the Timeswitch.
Severity Critical
Description The Diagnostic failed to remove a connection between two channels on the indicated Board's sixth DSP. Timeswitch software returned an error for a "Disconnect" request.
Impact The Timeswitch's memory elements could be faulty. Call processing using the indicated Board's first could be greatly impacted.
Recovery Action The Timeswitch's memory elements could be faulty. Run the Timeswitch Memory Diagnostic, and then re-run the diagnostic which failed to further test the behavior of the Timeswitch.
Technical Support Action The Timeswitch's memory elements could be faulty. Run the Timeswitch Memory Diagnostic, and then re-run the diagnostic which failed to further test the behavior of the Timeswitch.
Severity Critical
Description The Diagnostic failed to enable Board #1's Timeswitch. Timeswitch software returned an error in response to an "Enable" request.
Impact The Timeswitch's memory elements could be faulty. Call processing using the indicated Board's first could be greatly impacted.
Recovery Action Board #1's Timeswitch memory elements could be faulty. Run the Timeswitch Memory Diagnostic to further test the behaviour of the Timeswitch.
Technical Support Action Board #1's Timeswitch memory elements could be faulty. Run the Timeswitch Memory Diagnostic to further test the behaviour of the Timeswitch.
Severity Critical
Description The Diagnostic failed to enable Board #2's Timeswitch. Timeswitch software returned an error in response to an "Enable" request.
Impact The Timeswitch's memory elements could be faulty. Call processing using the indicated Board's first could be greatly impacted.
Recovery Action Board #2's Timeswitch memory elements could be faulty. Run the Timeswitch Memory Diagnostic to further test the behaviour of the Timeswitch.
Technical Support Action Board #2's Timeswitch memory elements could be faulty. Run the Timeswitch Memory Diagnostic to further test the behaviour of the Timeswitch.
Severity Critical
Description The Diagnostic failed to enable Board #3's Timeswitch. Timeswitch software returned an error in response to an "Enable" request.
Impact The Timeswitch's memory elements could be faulty. Call processing using the indicated Board's first could be greatly impacted.
Recovery Action Board #3's Timeswitch memory elements could be faulty. Run the Timeswitch Memory Diagnostic to further test the behaviour of the Timeswitch.
Technical Support Action Board #3's Timeswitch memory elements could be faulty. Run the Timeswitch Memory Diagnostic to further test the behaviour of the Timeswitch.
Severity Critical
Description The Diagnostic failed to enable Board #4's Timeswitch. Timeswitch software returned an error in response to an "Enable" request.
Impact The Timeswitch's memory elements could be faulty. Call processing using the indicated Board's first could be greatly impacted.
Recovery Action Board #4's Timeswitch memory elements could be faulty. Run the Timeswitch Memory Diagnostic to further test the behaviour of the Timeswitch.
Technical Support Action Board #4's Timeswitch memory elements could be faulty. Run the Timeswitch Memory Diagnostic to further test the behaviour of the Timeswitch.
Severity Critical
Description The Diagnostic failed to enable Board #5's Timeswitch. Timeswitch software returned an error in response to an "Enable" request.
Impact The Timeswitch's memory elements could be faulty. Call processing using the indicated Board's first could be greatly impacted.
Recovery Action Board #5's Timeswitch memory elements could be faulty. Run the Timeswitch Memory Diagnostic to further test the behaviour of the Timeswitch.
Technical Support Action Board #5's Timeswitch memory elements could be faulty. Run the Timeswitch Memory Diagnostic to further test the behaviour of the Timeswitch.
Severity Critical
Description The Diagnostic failed to disable Board #1's Timeswitch. Timeswitch software returned an error in response to a "Disable" request.
Impact The Timeswitch's memory elements could be faulty. Call processing using the indicated Board's first could be greatly impacted.
Recovery Action Board #1's Timeswitch memory elements could be faulty. Run the Timeswitch Memory Diagnostic to further test the behaviour of the Timeswitch.
Technical Support Action Board #1's Timeswitch memory elements could be faulty. Run the Timeswitch Memory Diagnostic to further test the behaviour of the Timeswitch.
Severity Critical
Description The Diagnostic failed to disable Board #2's Timeswitch. Timeswitch software returned an error in response to an "Disable" request.
Impact The Timeswitch's memory elements could be faulty. Call processing using the indicated Board's first could be greatly impacted.
Recovery Action Board #2's Timeswitch memory elements could be faulty. Run the Timeswitch Memory Diagnostic to further test the behaviour of the Timeswitch.
Technical Support Action Board #2's Timeswitch memory elements could be faulty. Run the Timeswitch Memory Diagnostic to further test the behaviour of the Timeswitch.
Severity Critical
Description The Diagnostic failed to disable Board #3's Timeswitch. Timeswitch software returned an error in response to a "Disable" request.
Impact The Timeswitch's memory elements could be faulty. Call processing using the indicated Board's first could be greatly impacted.
Recovery Action Board #3's Timeswitch memory elements could be faulty. Run the Timeswitch Memory Diagnostic to further test the behaviour of the Timeswitch.
Technical Support Action Board #3's Timeswitch memory elements could be faulty. Run the Timeswitch Memory Diagnostic to further test the behaviour of the Timeswitch.
Severity Critical
Description The Diagnostic failed to disable Board #4's Timeswitch. Timeswitch software returned an error in response to a "Disable" request.
Impact The Timeswitch's memory elements could be faulty. Call processing using the indicated Board's first could be greatly impacted.
Recovery Action Board #4's Timeswitch memory elements could be faulty. Run the Timeswitch Memory Diagnostic to further test the behaviour of the Timeswitch.
Technical Support Action Board #4's Timeswitch memory elements could be faulty. Run the Timeswitch Memory Diagnostic to further test the behaviour of the Timeswitch.
Severity Critical
Description The Diagnostic failed to disable Board #5's Timeswitch. Timeswitch software returned an error in response to a "Disable" request.
Impact The Timeswitch's memory elements could be faulty. Call processing using the indicated Board's first could be greatly impacted.
Recovery Action Board #5's Timeswitch memory elements could be faulty. Run the Timeswitch Memory Diagnostic to further test the behaviour of the Timeswitch.
Technical Support Action Board #5's Timeswitch memory elements could be faulty. Run the Timeswitch Memory Diagnostic to further test the behaviour of the Timeswitch.
Severity Critical
Description The Timeswitch Memory Diagnostic test on Board #1's Timeswitch failed. The Diagnostic was unable to write to the Timeswitch's TAP memory.
Impact The Timeswitch's memory elements could be faulty. Call processing using Board #1 could be greatly impacted.
Recovery Action The Timeswitch memory elements on Board #1 could be faulty. Repeat the test to confirm the failure.
Technical Support Action The Timeswitch memory elements on Board #1 could be faulty. Repeat the test to confirm the failure. If the failure persists then the Timeswitch on Board #1 will require replacement.switch.
Severity Critical
Description The Timeswitch Memory Diagnostic test on Board #2's Timeswitch failed. The Diagnostic was unable to write to the Timeswitch's TAP memory.
Impact The Timeswitch's memory elements could be faulty. Call processing using Board #2 could be greatly impacted.
Recovery Action The Timeswitch memory elements on Board #2 could be faulty. Repeat the test to confirm the failure.
Technical Support Action The Timeswitch memory elements on Board #2 could be faulty. Repeat the test to confirm the failure. If the failure persists then the Timeswitch on Board #2 will require replacement.
Severity Critical
Description The Timeswitch Memory Diagnostic test on Board #3's Timeswitch failed. The Diagnostic was unable to write to the Timeswitch's TAP memory.
Impact The Timeswitch's memory elements could be faulty. Call processing using Board #3 could be greatly impacted.
Recovery Action The Timeswitch memory elements on Board #3 could be faulty. Repeat the test to confirm the failure.
Technical Support Action The Timeswitch memory elements on Board #3 could be faulty. Repeat the test to confirm the failure. If the failure persists then the Timeswitch on Board #3 will require replacement.
Severity Critical
Description The Timeswitch Memory Diagnostic test on Board #4's Timeswitch failed. The Diagnostic was unable to write to the Timeswitch's TAP memory.
Impact The Timeswitch's memory elements could be faulty. Call processing using Board #4 could be greatly impacted.
Recovery Action The Timeswitch memory elements on Board #4 could be faulty. Repeat the test to confirm the failure.
Technical Support Action The Timeswitch memory elements on Board #4 could be faulty. Repeat the test to confirm the failure. If the failure persists then the Timeswitch on Board #4 will require replacement.
Severity Critical
Description The Timeswitch Memory Diagnostic test on Board #5's Timeswitch failed. The Diagnostic was unable to write to the Timeswitch's TAP memory.
Impact The Timeswitch's memory elements could be faulty. Call processing using Board #5 could be greatly impacted.
Recovery Action The Timeswitch memory elements on Board #5 could be faulty. Repeat the test to confirm the failure.
Technical Support Action The Timeswitch memory elements on Board #5 could be faulty. Repeat the test to confirm the failure. If the failure persists then the Timeswitch on Board #5 will require replacement.
Severity Critical
Description The Diagnostic test on Board #1's Timeswitch failed. The Diagnostic was unable to write to the Timeswitch's UNUSED TAP memory.
Impact The Timeswitch's memory elements could be faulty. Call processing using Board #1 could be greatly impacted.
Recovery Action The Timeswitch memory elements on Board #1 could be faulty. Run the Timeswitch Memory Diagnostic to confirm the result.
Technical Support Action The Timeswitch memory elements on Board #1 could be faulty. Run the Timeswitch Memory Diagnostic to confirm the result. If the failure persists then the Timeswitch on Board #1 will require replacement.
Severity Critical
Description The Diagnostic test on Board #2's Timeswitch failed. The Diagnostic was unable to write to the Timeswitch's UNUSED TAP memory.
Impact The Timeswitch's memory elements could be faulty. Call processing using Board #2 could be greatly impacted.
Recovery Action The Timeswitch memory elements on Board #2 could be faulty. Run the Timeswitch Memory Diagnostic to confirm the result.
Technical Support Action The Timeswitch memory elements on Board #2 could be faulty. Run the Timeswitch Memory Diagnostic to confirm the result. If the failure persists then the Timeswitch on Board #2 will require replacement.
Severity Critical
Description The Diagnostic test on Board #3's Timeswitch failed. The Diagnostic was unable to write to the Timeswitch's UNUSED TAP memory.
Impact The Timeswitch's memory elements could be faulty. Call processing using Board #3 could be greatly impacted.
Recovery Action The Timeswitch memory elements on Board #3 could be faulty. Run the Timeswitch Memory Diagnostic to confirm the result.
Technical Support Action The Timeswitch memory elements on Board #3 could be faulty. Run the Timeswitch Memory Diagnostic to confirm the result. If the failure persists then the Timeswitch on Board #3 will require replacement.
Severity Critical
Description The Diagnostic test on Board #4's Timeswitch failed. The Diagnostic was unable to write to the Timeswitch's UNUSED TAP memory.
Impact The Timeswitch's memory elements could be faulty. Call processing using Board #4 could be greatly impacted.
Recovery Action The Timeswitch memory elements on Board #4 could be faulty. Run the Timeswitch Memory Diagnostic to confirm the result.
Technical Support Action The Timeswitch memory elements on Board #4 could be faulty. Run the Timeswitch Memory Diagnostic to confirm the result. If the failure persists then the Timeswitch on Board #4 will require replacement.
Severity Critical
Description The Diagnostic test on Board #5's Timeswitch failed. The Diagnostic was unable to write to the Timeswitch's UNUSED TAP memory.
Impact The Timeswitch's memory elements could be faulty. Call processing using Board #5 could be greatly impacted.
Recovery Action The Timeswitch memory elements on Board #5 could be faulty. Run the Timeswitch Memory Diagnostic to confirm the result.
Technical Support Action The Timeswitch memory elements on Board #5 could be faulty. Run the Timeswitch Memory Diagnostic to confirm the result. If the failure persists then the Timeswitch on Board #5 will require replacement.
Severity Critical
Description The Diagnostic test on Board #1's Timeswitch failed. The Diagnostic was unable to write to the Timeswitch's CONNECTION memory.
Impact The Timeswitch's memory elements could be faulty. Call processing using Board #1 could be greatly impacted.
Recovery Action The Timeswitch memory elements on Board #1 could be faulty. Run the Timeswitch Memory Diagnostic to confirm the result.
Technical Support Action The Timeswitch memory elements on Board #1 could be faulty. Run the Timeswitch Memory Diagnostic to confirm the result. If the failure persists then the Timeswitch on Board #1 will require replacement.
Severity Critical
Description The Diagnostic test on Board #2's Timeswitch failed. The Diagnostic was unable to write to the Timeswitch's CONNECTION memory.
Impact The Timeswitch's memory elements could be faulty. Call processing using Board #2 could be greatly impacted.
Recovery Action The Timeswitch memory elements on Board #2 could be faulty. Run the Timeswitch Memory Diagnostic to confirm the result.
Technical Support Action The Timeswitch memory elements on Board #2 could be faulty. Run the Timeswitch Memory Diagnostic to confirm the result. If the failure persists then the Timeswitch on Board #2 will require replacement.
Severity Critical
Description The Diagnostic test on Board #3's Timeswitch failed. The Diagnostic was unable to write to the Timeswitch's CONNECTION memory.
Impact The Timeswitch's memory elements could be faulty. Call processing using Board #3 could be greatly impacted.
Recovery Action The Timeswitch memory elements on Board #3 could be faulty. Run the Timeswitch Memory Diagnostic to confirm the result.
Technical Support Action The Timeswitch memory elements on Board #3 could be faulty. Run the Timeswitch Memory Diagnostic to confirm the result. If the failure persists then the Timeswitch on Board #3 will require replacement.
Severity Critical
Description The Diagnostic test on Board #4's Timeswitch failed. The Diagnostic was unable to write to the Timeswitch's CONNECTION memory.
Impact The Timeswitch's memory elements could be faulty. Call processing using Board #4 could be greatly impacted.
Recovery Action The Timeswitch memory elements on Board #4 could be faulty. Run the Timeswitch Memory Diagnostic to confirm the result.
Technical Support Action The Timeswitch memory elements on Board #4 could be faulty. Run the Timeswitch Memory Diagnostic to confirm the result. If the failure persists then the Timeswitch on Board #4 will require replacement.
Severity Critical
Description The Diagnostic test on Board #5's Timeswitch failed. The Diagnostic was unable to write to the Timeswitch's CONNECTION memory.
Impact The Timeswitch's memory elements could be faulty. Call processing using Board #5 could be greatly impacted.
Recovery Action The Timeswitch memory elements on Board #5 could be faulty. Run the Timeswitch Memory Diagnostic to confirm the result.
Technical Support Action The Timeswitch memory elements on Board #5 could be faulty. Run the Timeswitch Memory Diagnostic to confirm the result. If the failure persists then the Timeswitch on Board #5 will require replacement.
Severity Critical
Description The Diagnostic test on Board #1's Timeswitch failed. The Diagnostic was unable to read from the Timeswitch's TAP memory.
Impact The Timeswitch's memory elements could be faulty. Call processing using Board #1 could be greatly impacted.
Recovery Action The Timeswitch memory elements on Board #1 could be faulty. Run the Timeswitch Memory Diagnostic to confirm the result.
Technical Support Action The Timeswitch memory elements on Board #1 could be faulty. Run the Timeswitch Memory Diagnostic to confirm the result. If the failure persists then the Timeswitch on Board #1 will require replacement.
Severity Critical
Description The Diagnostic test on Board #2's Timeswitch failed. The Diagnostic was unable to read from the Timeswitch's TAP memory.
Impact The Timeswitch's memory elements could be faulty. Call processing using Board #2 could be greatly impacted.
Recovery Action The Timeswitch memory elements on Board #2 could be faulty. Run the Timeswitch Memory Diagnostic to confirm the result.
Technical Support Action The Timeswitch memory elements on Board #2 could be faulty. Run the Timeswitch Memory Diagnostic to confirm the result. If the failure persists then the Timeswitch on Board #2 will require replacement.
Severity Critical
Description The Diagnostic test on Board #3's Timeswitch failed. The Diagnostic was unable to read from the Timeswitch's TAP memory.
Impact The Timeswitch's memory elements could be faulty. Call processing using Board #3 could be greatly impacted.
Recovery Action The Timeswitch memory elements on Board #3 could be faulty. Run the Timeswitch Memory Diagnostic to confirm the result.
Technical Support Action The Timeswitch memory elements on Board #3 could be faulty. Run the Timeswitch Memory Diagnostic to confirm the result. If the failure persists then the Timeswitch on Board #3 will require replacement.
Severity Critical
Description The Diagnostic test on Board #4's Timeswitch failed. The Diagnostic was unable to read from the Timeswitch's TAP memory.
Impact The Timeswitch's memory elements could be faulty. Call processing using Board #4 could be greatly impacted.
Recovery Action The Timeswitch memory elements on Board #4 could be faulty. Run the Timeswitch Memory Diagnostic to confirm the result.
Technical Support Action The Timeswitch memory elements on Board #4 could be faulty. Run the Timeswitch Memory Diagnostic to confirm the result. If the failure persists then the Timeswitch on Board #4 will require replacement.
Severity Critical
Description The Diagnostic test on Board #5's Timeswitch failed. The Diagnostic was unable to read from the Timeswitch's TAP memory.
Impact The Timeswitch's memory elements could be faulty. Call processing using Board #5 could be greatly impacted.
Recovery Action The Timeswitch memory elements on Board #5 could be faulty. Run the Timeswitch Memory Diagnostic to confirm the result.
Technical Support Action The Timeswitch memory elements on Board #5 could be faulty. Run the Timeswitch Memory Diagnostic to confirm the result. If the failure persists then the Timeswitch on Board #5 will require replacement.
Severity Critical
Description The Timeswitch Memory Diagnostic test on Board #1's Timeswitch failed. The Diagnostic was unable to read from the Timeswitch's CONNECTION memory.
Impact The Timeswitch's memory elements could be faulty. Call processing using Board #1 could be greatly impacted.
Recovery Action The Timeswitch memory elements on Board #1 could be faulty. Repeat the test to confirm the failure.
Technical Support Action The Timeswitch memory elements on Board #1 could be faulty. Repeat the test to confirm the failure. If the failure persists then the Timeswitch on Board #1 will require replacement.
Severity Critical
Description The Timeswitch Memory Diagnostic test on Board #2's Timeswitch failed. The Diagnostic was unable to read from the Timeswitch's CONNECTION memory.
Impact The Timeswitch's memory elements could be faulty. Call processing using Board #2 could be greatly impacted.
Recovery Action The Timeswitch memory elements on Board #2 could be faulty. Repeat the test to confirm the failure.
Technical Support Action The Timeswitch memory elements on Board #2 could be faulty. Repeat the test to confirm the failure. If the failure persists then the Timeswitch on Board #2 will require replacement.
Severity Critical
Description The Timeswitch Memory Diagnostic test on Board #3's Timeswitch failed. The Diagnostic was unable to read from the Timeswitch's CONNECTION memory.
Impact The Timeswitch's memory elements could be faulty. Call processing using Board #3 could be greatly impacted.
Recovery Action The Timeswitch memory elements on Board #3 could be faulty. Repeat the test to confirm the failure.
Technical Support Action The Timeswitch memory elements on Board #3 could be faulty. Repeat the test to confirm the failure. If the failure persists then the Timeswitch on Board #3 will require replacement.
Severity Critical
Description The Timeswitch Memory Diagnostic test on Board #4's Timeswitch failed. The Diagnostic was unable to read from the Timeswitch's CONNECTION memory.
Impact The Timeswitch's memory elements could be faulty. Call processing using Board #4 could be greatly impacted.
Recovery Action The Timeswitch memory elements on Board #4 could be faulty. Repeat the test to confirm the failure.
Technical Support Action The Timeswitch memory elements on Board #4 could be faulty. Repeat the test to confirm the failure. If the failure persists then the Timeswitch on Board #4 will require replacement.
Severity Critical
Description The Timeswitch Memory Diagnostic test on Board #5's Timeswitch failed. The Diagnostic was unable to read from the Timeswitch's CONNECTION memory.
Impact The Timeswitch's memory elements could be faulty. Call processing using Board #5 could be greatly impacted.
Recovery Action The Timeswitch memory elements on Board #5 could be faulty. Repeat the test to confirm the failure.
Technical Support Action The Timeswitch memory elements on Board #5 could be faulty. Repeat the test to confirm the failure. If the failure persists then the Timeswitch on Board #5 will require replacement.
Severity Critical
Description The Timeswitch Memory Diagnostic test on Board #1's Timeswitch failed. The Diagnostic was unable to read from the Timeswitch's UNUSED TAP memory.
Impact The Timeswitch's memory elements could be faulty. Call processing using Board #1 could be greatly impacted.
Recovery Action The Timeswitch memory elements on Board #1 could be faulty. Repeat the test to confirm the failure.
Technical Support Action The Timeswitch memory elements on Board #1 could be faulty. Repeat the test to confirm the failure. If the failure persists then the Timeswitch on Board #1 will require replacement.
Severity Critical
Description The Timeswitch Memory Diagnostic test on Board #2's Timeswitch failed. The Diagnostic was unable to read from the Timeswitch's UNUSED TAP memory.
Impact The Timeswitch's memory elements could be faulty. Call processing using Board #2 could be greatly impacted.
Recovery Action The Timeswitch memory elements on Board #2 could be faulty. Repeat the test to confirm the failure.
Technical Support Action The Timeswitch memory elements on Board #2 could be faulty. Repeat the test to confirm the failure. If the failure persists then the Timeswitch on Board #2 will require replacement.
Severity Critical
Description The Timeswitch Memory Diagnostic test on Board #3's Timeswitch failed. The Diagnostic was unable to read from the Timeswitch's UNUSED TAP memory.
Impact The Timeswitch's memory elements could be faulty. Call processing using Board #3 could be greatly impacted.
Recovery Action The Timeswitch memory elements on Board #3 could be faulty. Repeat the test to confirm the failure.
Technical Support Action The Timeswitch memory elements on Board #3 could be faulty. Repeat the test to confirm the failure. If the failure persists then the Timeswitch on Board #3 will require replacement.
Severity Critical
Description The Timeswitch Memory Diagnostic test on Board #4's Timeswitch failed. The Diagnostic was unable to read from the Timeswitch's UNUSED TAP memory.
Impact The Timeswitch's memory elements could be faulty. Call processing using Board #4 could be greatly impacted.
Recovery Action The Timeswitch memory elements on Board #4 could be faulty. Repeat the test to confirm the failure.
Technical Support Action The Timeswitch memory elements on Board #4 could be faulty. Repeat the test to confirm the failure. If the failure persists then the Timeswitch on Board #4 will require replacement.
Severity Critical
Description The Timeswitch Memory Diagnostic test on Board #5's Timeswitch failed. The Diagnostic was unable to read from the Timeswitch's UNUSED TAP memory.
Impact The Timeswitch's memory elements could be faulty. Call processing using Board #5 could be greatly impacted.
Recovery Action The Timeswitch memory elements on Board #5 could be faulty. Repeat the test to confirm the failure.
Technical Support Action The Timeswitch memory elements on Board #5 could be faulty. Repeat the test to confirm the failure. If the failure persists then the Timeswitch on Board #5 will require replacement.
Severity Major
Description The Timeswitch Local Loop-Back Diagnostic can only be run on platforms that contain an SCBUS Cable. IPE platforms do not possess an SCBUS cable.
Impact The Local Loop-Back Diagnostic will not function as expected.
Recovery Action Do not attempt to invoke the Timeswitch Local Loop-Back Diagnostic on IPE platforms.
Technical Support Action Do not attempt to invoke the Timeswitch Local Loop-Back Diagnostic on IPE platforms.
Severity Major
Description The indicated Board's first DSP device could not be reset.
Impact The DSP might not be present or might be defective. The DSP can not be used for call processing and must be disabled.
Recovery Action The DSP might be defective. Confirm the results of the diagnostic by running the DSP Diagnostics.
Technical Support Action Ensure that the indicated DSP is properly plugged in if it is a PCMCIA DSP. Using Microsoft's "Windows NT Diagnostics" utility to ensure that the "ntbus.sys" and "c52.sys" device drivers are installed and that the indicated DSP device was created.
Severity Major
Description The indicated Board's second DSP device could not be reset.
Impact The DSP might not be present or might be defective. The DSP can not be used for call processing and must be disabled.
Recovery Action The DSP might be defective. Confirm the results of the diagnostic by running the DSP Diagnostics.
Technical Support Action Ensure that the indicated DSP is properly plugged in if it is a PCMCIA DSP. Using Microsoft's "Windows NT Diagnostics" utility to ensure that the "ntbus.sys" and "c52.sys" device drivers are installed and that the indicated DSP device was created.
Severity Major
Description The indicated Board's third DSP device could not be reset.
Impact The DSP might not be present or might be defective. The DSP can not be used for call processing and must be disabled.
Recovery Action The DSP might be defective. Confirm the results of the diagnostic by running the DSP Diagnostics.
Technical Support Action Ensure that the indicated DSP is properly plugged in if it is a PCMCIA DSP. Using Microsoft's "Windows NT Diagnostics" utility to ensure that the "ntbus.sys" and "c52.sys" device drivers are installed and that the indicated DSP device was created.
Severity Major
Description The indicated Board's fourth DSP device could not be reset.
Impact The DSP might not be present or might be defective. The DSP can not be used for call processing and must be disabled.
Recovery Action The DSP might be defective. Confirm the results of the diagnostic by running the DSP Diagnostics.
Technical Support Action Ensure that the indicated DSP is properly plugged in if it is a PCMCIA DSP. Using Microsoft's "Windows NT Diagnostics" utility to ensure that the "ntbus.sys" and "c52.sys" device drivers are installed and that the indicated DSP device was created.
Severity Major
Description The indicated Board's fifth DSP device could not be reset.
Impact The DSP might not be present or might be defective. The DSP can not be used for call processing and must be disabled.
Recovery Action The DSP might be defective. Confirm the results of the diagnostic by running the DSP Diagnostics.
Technical Support Action Ensure that the indicated DSP is properly plugged in if it is a PCMCIA DSP. Using Microsoft's "Windows NT Diagnostics" utility to ensure that the "ntbus.sys" and "c52.sys" device drivers are installed and that the indicated DSP device was created.
Severity Major
Description The indicated Board's sixth DSP device could not be reset.
Impact The DSP might not be present or might be defective. The DSP can not be used for call processing and must be disabled.
Recovery Action The DSP might be defective. Confirm the results of the diagnostic by running the DSP Diagnostics.
Technical Support Action Ensure that the indicated DSP is properly plugged in if it is a PCMCIA DSP. Using Microsoft's "Windows NT Diagnostics" utility to ensure that the "ntbus.sys" and "c52.sys" device drivers are installed and that the indicated DSP device was created.
Severity Major
Description The Timeswitch CLI Diagnostic Tool failed to allocate memory.
Impact Overall system performance will be very slow. The selected diagnostic will not be run.
Recovery Action Please contact your technical support organization.
Technical Support Action Please contact your technical support organization.
Severity Major
Description A call to "nbdsp.dll" - Nbdsp_GetInstalledDSPs failed.
Impact The installed DSP(s) might be defective and call processing may be severly impacted.
Recovery Action Ensure that the "ntbus.sys" and "c52.sys" device drivers have been started by viewing the contents of the "Devices" applet in the Windows NT Control Panel Group. Please contact your technical support organization.
Technical Support Action Ensure that all DSPs are properly plugged in if they are PCMCIA DSPs. Using Microsoft's "Windows NT Diagnostics" utility to ensure that the "ntbus.sys" and "c52.sys" device drivers are installed and that the indicated DSP device was created.
Severity Critical
Description No devices that can be tested are installed on the system (No SCBUSes, NTBUSes, or DSPs).
Impact There are no SCBUSes, NTBUSes, or DSPs installed in the sytem - call processing might be severly impacted.
Recovery Action Ensure that the "ntbus.sys" and "c52.sys" device drivers have been started by viewing the contents of the "Devices" applet in the Windows NT Control Panel Group. Please contact your technical support organization.
Technical Support Action Ensure that all hardware is properly installeed in the system. Also ensure that the "ntbus.sys" and "c52.sys" device drivers have been started by viewing the contents of the "Devices" applet in the Windows NT Control Panel Group.
Severity Minor
Description An impossible code path was reached.
Impact The Timeswitch CLI Diagnostic Tool (nbtswdgn.exe) will not function as expected.
Recovery Action A software error occurred while executing the diagnostic. Please contact your technical support organization.
Technical Support Action A software error occurred while executing the diagnostic. Please contact your technical support organization.