PEP Read Me First
=================

PEP Number: CP202S03G20S
Pep Title:  Network wide broadcast messages fails to be delivered


(0) Target Release
==================
CallPilot 02.01.27.05 SU03


(1a) Target Platform
===================
CallPilot Server - 200i/201i/702t/703t/1001rp/1002rp


(1b) Affected Connectivities
============================
Meridian 1 / Succession 1000		


(2) Problem Description
=======================
A problem has been identified within CallPilot Networking where 
a network-wide-broadcast message from a telephone set fails to be 
delivered to local and remote network sites.   

CallPilot uses a MTA Service (Message Transfer Agent) to handle
message delivery. The MTA Service is mistreating the remote network 
messages and an exception is raised. If this problem is being 
experienced, the sender of the Network Wide Broadcast will receive 
a Non Delivery Notification (NDN) message and the recipients 
will not receive the message. Events 54101 and 54103 are raised and 
logged in the Application Event log file.

It is recommended that all systems that have more than one CallPilot 
configured in their networking tree install this PEP.  


(3) List of CRs that are fixed by this PEP 
=========================================
Q00988007-01 Network wide broadcast messages fails to be delivered


(4) Dependencies
================
This PEP requires the CP20127SU03S (SU03).

This PEP replaces CP202S03G12S
The replaced PEP will be automatically uninstalled when CP202S03G20S is installed.


(5) How to install this PEP
===========================
(i) Stop the following services, in the given order:
		
	1. CallPilot IMA service
	2. CallPilot MTA service

(ii) Copy the files as follows:

	#   File		Destination directory
	----------------------------------------------
	1. nmmtautl.dll		d:\nortel\mpcx\bin	// This PEP
	2. nmmtasrv.exe		d:\nortel\mpcx\bin	// This CP202S03G12S
	3. nmmtalds.dll		d:\nortel\mpcx\bin	// from CP202S03G05S
              
(iii) Start the following services, in the given order:
		
	1. CallPilot MTA service
	2. CallPilot IMA service

(iv) Reboot is not required

(v) MTA monitor utility must be terminated before the installation


(6) List of suggested test cases
================================
6.1 Ensure that there are two or more servers configured in the system.
6.2 Configure networking of any kind (AMIS, VPIM, etc.) in between them.
6.3 Send a network broadcast message.
6.4 Make certain that the message is delivered to all users at all servers.


(7) Special instructions
========================
None.